Search Results for: synthograft

NOTE: Some search term matches may be visible only within the gallery photo captions.
thumbnail

The Insertion of Two Contiguous Implants into a Mandibular Bone Void Using Sinus Lift Abutments with SynthoGraft®, and Their Subsequent Restoration with Two Integrated Abutment Crowns™

Posted on in Integrated Abutment Crowns™, SHORT® Implants

This treatment demonstrates the insertion of a 4.0 x 6.0mm implant and a 4.5 x 6.0mm implant into two contiguous mandibular osteotomies, which communicated with each other because of a bone void. After preparation of the implant osteotomies through the crest of cortical bone, the soft tissue content of the bone void was thoroughly removed from the bony walls of the defect with a spoon excavator prior to filling the defect with a putty-like consistency of the patient’s blood and SynthoGraft®, a pure-phase beta-tricalcium phosphate. A sinus lift abutment was used to prevent the implants from being displaced into the defect. Subsequently, the implants were restored with Universal Abutments and Integrated Abutment Crowns (IACs).

thumbnail

Guided Bone Regeneration Technique and Implant Placement in an atrophic mandibular first molar site

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Uncovering

This treatment offers an alternative to ridge splitting procedures, demonstrating the molar implant placement and simultaneous guided bone regeneration of a 56-year-old woman’s atrophic left mandible. Because of the very thin and dense crestal bone, a high-speed drill was used to initiate the osteotomy prior to the successive use of latch and hand reamers, and the placement of a 4.5 x 6.0mm implant, which was covered with SynthoGraft™ within a collagen membrane pocket. The 5-year post-insertion clinical and radiographic images reveal a successful treatment with significant bone gain.

thumbnail

Extraction of a Maxillary Left First Premolar and its Replacement with a SHORT® 4.5 x 6.0mm Implant, and Grafting with LPRF, Collagen Membranes, and SynthoGraft™, a pure phase beta tricalcium phosphate

Posted on in Extraction, Integrated Abutment Crowns™

This case demonstrates the extraction of a maxillary left first premolar and its replacement with a SHORT® 4.5 x 6.0mm implant using SynthoGraft™, Leukocyte and Platelet Rich Fibrin (LPRF), and collagen membranes. The osteotomy was carefully prepared using latch and hand reamers in 0.5mm increments despite a buccal bone perforation.

thumbnail

Placement and Restoration of a 3.0 x 6.0mm SHORT® Implant in a Seemingly Impossible Clinical Situation

Posted on in Immediate Placement, Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical

This case demonstrates three years of remarkable healing and clinical capabilities of a Bicon implant which was restored with an Integrated Abutment Crown™ (IAC) in a seventy-two-year-old male patient. Due to a variety of extenuating circumstances, a 3.0 x 6.0mm SHORT® Implant was immediately placed with a significant amount of SynthoGraft™, a pure phase beta tricalcium phosphate material, and a collagen membrane in a seemingly impossible clinical situation after the removal of a fractured and infected mandibular lateral incisor.

thumbnail

Maxillary Anterior Placement of a 4.0 x 8.0mm Bicon Implant with SynthoGraft™

Posted on in Surgical, Two Stage

This case demonstrates the two-stage placement of a maxillary anterior 4.0 x 8.0mm implant with SynthoGraft™ and Leukocyte and Platelet Rich Fibrin (LPRF).

thumbnail

External and Internal Sinus Lifts, Maxillary Metal-Free TRINIA™ Prosthesis

Posted on in Fixed, Restorative, Sinus Lifts, Surgical, Two Stage, Uncovering

This case demonstrates an external and internal sinus lift utilizing Piezosurgery® with SynthoGraft™ pure phase Beta-Tricalcium Phosphate, the two-stage maxillary placement of six Bicon implants, uncovering, implant-level transfer impression, and the clinical insertion techniques for a maxillary metal-free implant supported fixed TRINIA™ prosthesis on six Bicon implants.

thumbnail

Internal Sinus Lift with Synthograft™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Sinus Lifts, Surgical

This case demonstrates the surgical placement with an internal sinus lift procedure using SynthoGraft™ pure phase Beta-Tricalcium Phosphate, and the restoration of a 5.0 x 6.0mm Bicon SHORT® Implant with an Integrated Abutment Crown™.

thumbnail

Extraction, Bone Grafting, Placement, and Restoration of a 4.5 x 8.0mm Bicon Implant

Posted on in Extraction, Restorative, Surgical, Two Stage, Uncovering

This case demonstrates the extraction, bone grafting with SynthoGraft™, two-stage placement of a 4.5 x 8.0mm Bicon Integra-CP™ implant, and its restoration with a polyceramic veneered gold crown.

thumbnail

Internal Sinus Lift with SynthoGraft™, Two- Stage Placement of a 5.0mm x 6.0mm Short Implant, and Restoration with a Bicon Integrated Abutment Crown™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Sinus Lifts, Surgical, Two Stage

This case demonstrates the use of SynthoGraft™ pure phase Beta-Tricalcium Phosphate for an internal sinus lift, two-stage surgical placement of a 5.0mm x 6.0mm implant and a 6.5mm x 2.5mm Sinus Lift Temporary Abutment, an implant-level impression, and an insertion of an Integrated Abutment Crown™.

thumbnail

Two Implant-Retained Mandibular Overdenture

Posted on in Overdentures, Restorative, Surgical, Uncovering

This case demonstrates the placement of two implants and bone grafting with Synthograft™, uncovering of the implants, and insertion of two locator abutments with their metal housing caps integrated into the denture.

Page 1 of 212