|
Bicon Integrated Abutment Crowns™ / Immediate Stabilization and Function: Extraction, Immediate Placement and Stabilization of Five Bicon Implants and their Restoration with Integrated Abutment Crowns™
|
||
| First Clinical Visit: | ||
![]() |
1. | Pre-operative smile. |
![]() |
2. | Pre-operative radiograph. |
![]() |
3. | Pre-operative radiograph. |
![]() |
4. | Pre-operative radiograph. |
![]() |
5. | Pre-operative site. |
![]() |
6. | Prosthesis being removed in preparation for the implant placements. |
![]() |
7. | View of pre-operative site after the removal of the prosthesis. |
![]() |
8. | Extraction of tooth. |
![]() |
9. | Extraction of tooth. |
![]() |
10. | Extraction of tooth. |
![]() |
11. | Osteotomy being prepared with 2.0mm pilot bur rotating at 1100RPM with external irrigation. |
![]() |
12. | Osteotomy being prepared with 2.0mm pilot bur rotating at 1100RPM with external irrigation. |
![]() |
13. | Parallel pin confirming appropriate trajectory and acting as a guide for subsequent osteotomy. |
![]() |
14. | Parallel pins seated in pilot osteotomies indicating their trajectories. |
![]() |
15. | Osteotomy being enlarged with an olive green 2.5mm latch reamer bur rotating at 50 RPM without water irrigation. |
![]() |
16. | Osteotomy being enlarged with a teal 3.0mm latch reamer bur rotating at 50 RPM without water irrigation. |
![]() |
17. | Osteotomy being enlarged with a blue 3.5mm latch reamer bur rotating at 50 RPM without water irrigation. |
![]() |
18. | Osteotomy being enlarged with a red 4.0mm latch reamer bur rotating at 50 RPM without water irrigation. |
![]() |
19. | Osteotomy being enlarged with a silver 4.5mm hand reamer bur attached to a threaded straight handle. |
![]() |
20. | Osteotomy is being widened with a silver 4.5mm bone expander attached to a threaded straight handle. |
![]() |
21. | Osteotomy being enlarged with a gold 5.0mm hand reamer bur attached to a threaded straight handle. |
![]() |
22. | Depth gauge seated in the osteotomy to facilitate the selection of an implant with an appropriate length. |
![]() |
23. | A 4.5mm x 8.0mm HA coated implant with 3.0mm implant well being inserted into the osteotomy with the implant inserter/retriever device. |
![]() |
24. | A 4.5mm x 8.0mm HA coated implant with 3.0mm implant well being inserted into the osteotomy with the implant inserter/retriever device. |
![]() |
25. | A 4.5mm x 8.0mm HA coated implant with 3.0mm implant well being inserted into the osteotomy with the implant inserter/retriever device. |
![]() |
26. | A 5.0mm x 8.0mm HA coated implant with 3.0mm implant well being inserted into the osteotomy with the implant inserter/retriever device. |
![]() |
27. | View of wells of seated implants. |
![]() |
28. | A 5.0mm x 8.0mm HA coated implant with 3.0mm implant well being inserted into the osteotomy with the implant inserter/retriever device. |
![]() |
29. | Implant seating tip attached to a straight handle being tapped to seat implant farther into the osteotomy. |
![]() |
30. | Close-up view of implant seating tip attached to a straight handle being tapped to seat implant farther into the osteotomy. |
![]() |
31. | View of seated implants with polyethylene healing plugs. |
![]() |
32. | Post-operative radiograph. |
![]() |
33. | Post-operative radiograph. |
![]() |
34. | Tall acrylic sleeve being modified. |
![]() |
35. | A modified acrylic sleeve snapped onto a 4.0 x 3.5mm shouldered abutment being inserted into the implant well . |
![]() |
36. | Shoulder depth gauge seated in the well of the implant facilitates the selection of a stealth abutment with an appropriate shoulder height. |
![]() |
37. | A modified acrylic sleeve snapped onto a 4.0 x 3.5mm shouldered abutment being inserted into the implant well. |
![]() |
38. | Shoulder depth gauge seated in the well of the implant facilitates the selection of a stealth abutment with an appropriate shoulder height. |
![]() |
39. | Shoulder depth gauge seated in the well of the implant facilitates the selection of a stealth abutment with an appropriate shoulder height. |
![]() |
40. | A modified acrylic sleeve snapped onto a 4.0 x 3.5mm shouldered abutment being inserted into the implant well. |
![]() |
41. | Acrylic sleeve being adjusted for clearance. |
![]() |
42 | Vacuum formed template seated over acrylic sleeves and abutments to confirm the appropriateness of their placement. |
![]() |
43. | Vaseline being applied around the acrylic sleeves and shouldered abutments. |
![]() |
44. | Transitional composite material, “Integrity” by Dentsply, being added to acrylic sleeves to form a bonded strut between adjacent teeth. |
![]() |
45. | Transitional composite material, “Integrity” by Dentsply, being added to vacuum formed template to form a transitional stabilizing prosthesis. |
![]() |
46. | Additional transitional composite material, “Integrity” by Dentsply, in vacuum formed template added to the hardened strut for aesthetic contouring. |
![]() |
47. | Vacuum formed template being removed. |
![]() |
48. | Transitional composite prosthesis incorporating modified acrylic sleeves being removed for polishing. |
![]() |
49. | Polished transitional composite prosthesis being initially inserted. |
![]() |
50. | Vaseline being applied. |
![]() |
51. | Cement being applied. |
![]() |
52. | Transitional stabilizing prosthesis being cemented. |
![]() |
53. | Incisal contacts being adjusted. |
![]() |
54. | Post-operative radiograph. |
![]() |
55. | Post-operative radiograph. |
| Second Clinical Visit: | ||
![]() |
56. | Bonded transitional stabilizing prosthesis prior to its being removed at the patient’s second clinical visit. |
![]() |
57. | Transitional stabilizing prosthesis being removed for the making of an implant level transfer impression. |
![]() |
58. | View of implant wells and soft tissue sulci. |
![]() |
59. | Green 3.0mm metal guide pins being inserted. |
![]() |
60. | Green 3.0mm impression reamer being inserted onto guide pin to remove any tissue which might inhibit the complete seating of an impression post. |
![]() |
61. | Green 3.0mm plastic impression post being inserted into the 3.0mm well of an integrated implant for the making of an implant level transfer impression. |
![]() |
62. | Green 3.0mm plastic impression post receiving its mandatory seating tap. |
![]() |
63. | Impression material being injected around the impression post for the making of a full arch implant level transfer impression. |
![]() |
64. | Facial view with green 3.0mm plastic impression posts prior to the making of an occlusal registration. |
![]() |
65. | Polyvinylsiloxane material being injected for the recording of an occlusal registration. |
![]() |
66. | Occlusal registration being recorded. |
| Third Clinical Visit: | ||
![]() |
67. | Integrated Abutment Crowns™ on a stone model. |
![]() |
68. | View of five Integrated Abutment Crowns™. |
![]() |
69. | View of transitional prostheses prior to its removal for the insertion of the Integrated Abutment Crowns™. |
![]() |
70. | Transitional prostheses being removed. |
![]() |
71. | Well of implant being cleaned with alcohol on a cotton tipped applicator. |
![]() |
72. | Integrated Abutment Crown™ being inserted. |
![]() |
73. | Crestal relieving incision being made to facilitate the seating of the Integrated Abutment Crown™. |
![]() |
74. | Integrated Abutment Crown™ being inserted. |
![]() |
75. | Well of implant being cleaned with alcohol on a cotton tipped applicator. |
![]() |
76. | Integrated Abutment Crown™ being inserted. |
![]() |
77. | Crestal relieving incision being made to facilitate the seating of the Integrated Abutment Crown™. |
![]() |
78. | Well of implant being cleaned with alcohol on a cotton tipped applicator. |
![]() |
79. | Integrated Abutment Crown™ being inserted. |
![]() |
80. | Integrated Abutment Crown™ being inserted. |
![]() |
81. | An acrylic orientation jig being used to initially position the Integrated Abutment Crowns™. |
![]() |
82. | Floss being used to confirm the fact that the interproximal contacts are passive and will not interfere with the engagement of the locking taper. |
![]() |
83. | Diamond finishing strip being used to lighten the interproximal contact area eliminating the possibility that the contact may prevent the engagement of the locking taper connection. |
![]() |
84. | Facial view immediately after the insertion of five Integrated Abutment Crowns™. |
![]() |
85. | Yellow thermoplastic custom seating jig, which was formed with a crown alignment device, in a crown seating tip attached to a straight handle facilitates directing the tapping forces in the long axis of the abutment post and implant well. |
![]() |
86. | Yellow thermoplastic custom seating jig, which was formed with a crown alignment device, in a crown seating tip attached to a straight handle facilitates directing the tapping forces in the long axis of the abutment post and implant well. |
![]() |
87. | Yellow thermoplastic custom seating jig, which was formed with a crown alignment device, in a crown seating tip attached to a straight handle facilitates directing the tapping forces in the long axis of the abutment post and implant well. |
![]() |
88.. | Yellow thermoplastic custom seating jig, which was formed with a crown alignment device, in a crown seating tip attached to a straight handle facilitates directing the tapping forces in the long axis of the abutment post and implant well. |
![]() |
89. | Yellow thermoplastic custom seating jig, which was formed with a crown alignment device, in a crown seating tip attached to a straight handle facilitates directing the tapping forces in the long axis of the abutment post and implant well. |
![]() |
90. | Incisal contacts being adjusted. |
![]() |
91. | Facial view of the Integrated Abutment Crowns™ after the adjustment. Note how the initial blanching of the tissue is no longer present. |
![]() |
92. | Facial view of the Integrated Abutment Crowns™ in occlusion. |
![]() |
93. | Post-operative radiograph. |
![]() |
94. | Post-operative radiograph. |
![]() |
95. | Post-operative radiograph. |
![]() |
96. | Facial view two-week post insertion. |
![]() |
97. | Smile two-week post-insertion. |
|
||