|
Immediate Stabilization and Function / Bicon Integrated Abutment Crowns™ / Congenitally Missing Laterals:
Placement and Restoration of Two Implants and Crown Lengthening Surgery for Congenitally Missing Lateral Incisors.
|
||
![]() |
1. | Smile revealing congenitally missing lateral incisors. |
![]() |
2. | Congenitally missing lateral incisors. |
![]() |
3. | Orthodontic appliance replacing lateral incisors. |
![]() |
4. | Pre-operative radiograph. |
![]() |
5. | Left profile revealing passive eruption. |
![]() |
6. | Right profile revealing passive eruption. |
![]() |
7. | Left profile revealing passive eruption. |
![]() |
8. | Right profile revealing passive eruption. |
![]() |
9. | Pre-operative labial view. |
![]() |
10. | Etchant being applied for bonding surfaces prior to surgery. |
![]() |
11. | Primer agent being applied for bonding. |
![]() |
12. | Bonding agent being applied. |
![]() |
13. | Bonding agent being light cured. |
![]() |
14. | Evaluation prior to crown lengthening and implant placement surgery. |
![]() |
15. | Initial incision. |
![]() |
16. | Reflection of palatal tissue. |
![]() |
17. | Evaluation for crown lengthening surgery. |
![]() |
18. | Osteotomy being prepared with 2.0mm pilot bur. |
![]() |
19. | Paralleling pins confirming trajectory of osteotomies. |
![]() |
20. | Osteotomy being prepared with a 3.5mm blue latch reamer rotating at 50RPMs. |
![]() |
21. | A 3.5mm x 11mm HA coated implant being inserted into osteotomy. |
![]() |
22. | A 4.0mm x 3.5mm stealth abutment being inserted with only finger pressure into the implant. |
![]() |
23. | A tall 4.0mm acrylic sleeve being inserted onto the stealth abutment. |
![]() |
24. | Two acrylic sleeves on stealth abutments. |
![]() |
25. | Acrylic sleeve being reduced. |
![]() |
26. | Trimmed acrylic sleeve. |
![]() |
27. | Polyceramic material being added to acrylic sleeve to form a bonded strut between adjacent teeth. |
![]() |
28. | Additional polyceramic material in vacuum formed template being added to the hardened strut for aesthetic contouring. |
![]() |
29. | Polyceramic stabilization prostheses being light cured |
![]() |
30. | Two three-unit transitional stabilization prostheses in place. |
![]() |
31. | Right labial view after crown lengthening surgery. |
![]() |
32. | Left labial view after crown lengthening surgery. |
![]() |
33. | Smile immediately after implant placement. |
![]() |
34. | Radiograph of immediately stabilized implants. |
![]() |
35. | Stabilization prostheses seven weeks after implant placement. |
![]() |
36. | Two 4.0mm x 3.5mm stealth abutments after removal of stabilization prostheses. |
![]() |
37. | Implant wells and soft tissue sulci after removal of stealth abutments. |
![]() |
38. | A 2.0mm black plastic impression post being inserted into 2.0mm implant well. |
![]() |
39. | Impression post being fully seated into the well of the implant with multiple gentle taps. |
![]() |
40. | Two seated 2.0mm black impression posts. |
![]() |
41. | Impression material being injected around posts for the making of an implant level transfer impression. |
![]() |
42. | Digital photo being taken of shade guide against a black metallic background. |
![]() |
43. | Two Integrated Abutment Crowns™ on stone model with clear acrylic orientation jig. |
![]() |
44. | Mirror view of two Integrated Abutment Crowns™. |
![]() |
45. | Two 4.0mm stealth abutments prior to their being removed. |
![]() |
46. | Implant wells and sulci after removal of stealth abutments. |
![]() |
47. | Two guide pins seated in the implant wells indicating the trajectory of the implants. |
![]() |
48. | Right lateral incisor Integrated Abutment Crown™ being inserted. |
![]() |
49. | Orientation jig being stabilized with cotton rolls during initial placement of Integrated Abutment Crowns™. |
![]() |
50. | Crestal relieving incision being made to facilitate the seating of the Integrated Abutment Crown™. |
![]() |
51. | Relieving incision being made leaving a thin piece of tissue along adjacent tooth. |
![]() |
52. | Orientation jig being used to initially seat right lateral incisor. |
![]() |
53. | Right lateral incisor being definitively seated with six taps with a white temporary abutment inserted into a straight driver. |
![]() |
54. | Left lateral incisor being initially seated with an orientation jig. |
![]() |
55. | White temporary abutment in a straight driver being used to definitively seat the Integrated Abutment Crown™ in the long axis of the implant well. |
![]() |
56. | Seated Integrated Abutment Crowns™. |
![]() |
57. | Radiograph of seated Integrated Abutment Crowns™. |
![]() |
58. | Six weeks after insertion of Integrated Abutment Crowns™. |
![]() |
59. | Six weeks after insertion of Integrated Abutment Crowns™. |
![]() |
60. | Restored congenitally missing lateral incisors six weeks after insertion of Bicon Integrated Abutment Crowns™. |
![]() |
61. | Three-years post insertion view. |
![]() |
62. | Three-years post insertion view. |
![]() |
63. | Three-years post insertion view. |
![]() |
64. | Four-year post insertion view. |
![]() |
65. | Four-year post insertion view. |
![]() |
66. | Four-year post insertion view. |
![]() |
67. | Four-year post insertion radiograph. |
![]() |
68. | Five-year post insertion right profile view. |
![]() |
69. | Five-year post insertion left profile view. |
![]() |
70. | Five-year post insertion view of patient's smile. |
|
||