|
Immediate Stabilization and Function / Bicon Integrated Abutment Crowns™: Extraction, Placement and Restoration of Immediately Placed and Functioning Maxillary Right Central Incisor Implant with Integrated Abutment Crown™ |
||
![]() |
1. | Pre-operative smile. |
![]() |
2. | Pre-operative radiograph. |
![]() |
3. | Pre-operative site. |
![]() |
4. | Bonding primer agent being applied. |
![]() |
5. | Bonding agent being applied. |
![]() |
6. | Light curing of bonding agent. |
![]() |
7. | Extraction of failed endodontically treated tooth. |
![]() |
8. | Osteotomy being prepared with 2.0mm pilot bur rotating at 1100RPM with external irrigation. |
![]() |
9. | Paralleling pin seated in pilot osteotomy indicating its trajectory. |
![]() |
10. | Clinician’s finger monitoring the buccal bone during the preparation of the osteotomy and the harvesting of bone with an olive green 2.5mm latch reamer rotating at 50RPM. |
![]() |
11. | Osteotomy being enlarged with a teal 3.0mm latch reamer bur rotating at 50RPM without water irrigation. |
![]() |
12. | Clinician’s finger monitoring the buccal bone during the preparation of the osteotomy and the harvesting of bone with a red 4.0mm latch reamer rotating at 50RPM. |
![]() |
13. | A 4.5mm hand reamer attached to a straight handle is being rotated to enlarge the osteotomy. |
![]() |
14. | Curette removing residual bone while confirming the integrity of the five bony walls of the osteotomy. |
![]() |
15. | A 4.5mm x 8.0mm HA coated implant being inserted into the osteotomy with the implant inserter/retriever device. |
![]() |
16. | 4.5mm x 8.0mm HA coated implant being definitively seated into osteotomy with an implant seating tip threaded on a straight driver. |
![]() |
17. | Shoulder depth gauge seated in the well of the implant facilitates the selection of a stealth abutment with an appropriate shoulder height. |
![]() |
18. | Stealth shouldered abutment 4.0mm wide with a shoulder height of 3.5mm is being inserted into the implant well. |
![]() |
19. | Stealth shouldered abutment 4.0mm wide with a shoulder height of 3.5mm is inserted into the implant well with only finger pressure. |
![]() |
20. | Tall acrylic sleeve is being placed onto stealth abutment. |
![]() |
21. | Tall acrylic sleeve is being modified. |
![]() |
22. | Tall acrylic sleeve is being modified. |
![]() |
23. | Polyceramic material being added to an acrylic sleeve to form a strut. |
![]() |
24. | Light curing of polyceramic material that was applied over the acrylic sleeve. |
![]() |
25. | Material is being added to facilitate the aesthetic contouring of the strut. |
![]() |
26. | Transitional stabilizing prosthesis being light cured. |
![]() |
27. | Prosthesis prior to final polishing. |
![]() |
28. | Radiograph of immediately placed and functioning implant at the completion of the first clinical visit. |
![]() |
29. | View of transitional prosthesis prior to its removal nine weeks after implant placement. |
![]() |
30. | View of transitional abutment after removal of splinted prosthesis. |
![]() |
31. | View of implant well after the removal of the transitional prosthesis and the stealth abutment. |
![]() |
32. | Green 3.0mm impression reamer being inserted onto guide pin to remove any tissue which might inhibit the complete seating of an impression post. |
![]() |
33. | Green 3.0mm plastic impression post being inserted into the 3.0mm well of an integrated implant for the making of an implant level transfer impression. |
![]() |
34. | Green plastic impression post receiving its mandatory seating tap. |
![]() |
35. | Impression material being injected around the impression post for the making of a full arch implant level transfer impression. |
![]() |
36. | Digital image being taken of shade guides against a black plastic background to facilitate the fabrication of an aesthetic Integrated Abutment Crown™. |
![]() |
37. | Integrated Abutment Crown™ on dental model with acrylic orientation jig. |
![]() |
38. | Integrated Abutment Crown™ on stone model with yellow thermoplastic seating jigs which were fabricated on a caliper-like device to facilitate directing the seating forces in the long axis of the implant well and abutment post. |
![]() |
39. | View of Integrated Abutment Crown™. |
![]() |
40. | View of transitional prosthesis prior to its removal for the insertion of the Integrated Abutment Crown™. |
![]() |
41. | View of implant well and soft tissue sulcus. |
![]() |
42. | Abutment post being cleaned with alcohol wipe to remove any debris which could diminish the effectiveness of the locking taper connection. |
![]() |
43. | An Integrated Abutment Crown™ being inserted initially to evaluate its appropriateness. |
![]() |
44. | Palatal oblique incisions are being made to facilitate the seating of the Integrated abutment Crown™. |
![]() |
45. | A gold 5.0mm sulcus reamer being used to remove soft tissue and bone which might inhibit the complete seating of the Integrated Abutment Crown™. |
![]() |
46. | A gold 5.0mm sulcus reamer being used to remove soft tissue and bone. |
![]() |
47. | Floss being used to confirm the fact that the inter-proximal contacts are passive and will not interfere with the engagement of the locking taper. |
![]() |
48. | Clear orientation jig is being tapped to initially engage the locking taper connection of the Integrated Abutment Crown™. |
![]() |
49. | A yellow thermoplastic custom seating jig which was formed in a caliper-like device is seated in a crown seating tip attached to a straight handle to facilitate directing the tapping forces in the long axis of the abutment post and implant well. |
![]() |
50. | Blue markings indicate appropriate occlusal contacts in all extreme excursions while the patient is clenching. |
![]() |
51. | Facial view of seated Integrated Abutment Crown™ immediately after being inserted. |
![]() |
52. | Right profile view of seated Integrated Abutment Crown™ immediately after being inserted. |
![]() |
53. | Left profile view of seated Integrated Abutment Crown™ immediately after being inserted. |
![]() |
54. | Post-insertion radiograph of the Integrated Abutment Crown™. |
![]() |
55. | Gingivally aesthetic restoration after dissipation of the initial tissue blanching. |
![]() |
56. | Post insertion smile thirteen weeks after the extraction of the failed root canal treated tooth. |
![]() |
57. | Close-up of the right profile one week after the insertion of the Integrated Abutment Crown™. |
![]() |
58. | Close-up of the left profile one week after the insertion of the Integrated Abutment Crown™. |
![]() |
59. | Facial view one week after the insertion of the Integrated Abutment Crown™. |
![]() |
60. |
Patient’s smile one week after the insertion of the Integrated Abutment Crown™. |
![]() |
61. |
Seven weeks post-insertion image. |
|
||