Bicon Integrated Abutment Crowns™: Extraction, Two Stage Placement of Three Mandibular Implants, and their Restoration with Integrated Abutment Crowns™ This case demonstrates the extraction of two failed endodontically treated teeth for a three unit mandibular fixed prosthesis and the immediate two stage placement of two short 6.0mm x 5.7mm HA coated implants and the two stage placement of an additional implant as well as their restoration with Integrated Abutment Crowns™. |
||
![]() |
1. | Pre-operative radiograph. |
![]() |
2. | Extraction of a failed endodontically treated tooth. |
![]() |
3. | View of cracked root. |
![]() |
4. | Post-extraction site. |
![]() |
5. | Parallel pin confirming appropriate trajectory and acting as a guide for subsequent osteotomy. |
![]() |
6. | Osteotomy being prepared with 2.0mm pilot bur rotating at 1100rpm. |
![]() |
7. | Parallel pins seated in pilot osteotomies indicating their trajectories. |
![]() |
8. | Osteotomy being enlarged with a 5.0mm latch reamer bur rotating at 50rpm without water irrigation. |
![]() |
9. | Harvested bone within flute of latch reamer. |
![]() |
10. | Curette removing residual bone while confirming the integrity of the five bony walls of the osteotomy. |
![]() |
11. | A short 6.0mm x 5.7mm HA coated is being inserted with a black polyethylene healing plug. |
![]() |
12. | View of healing plugs in the inserted implants. |
![]() |
13. | View of healing plugs in the inserted implants. |
![]() |
14. | Implant being seated into the osteotomy by the tapping of the black healing plug with an implant seating tip attached to a straight handle. |
![]() |
15. | Implant being seated into the osteotomy by the tapping of the black healing plug with an implant seating tip attached to a straight handle. |
![]() |
16. | View of seated implant with cut polyethylene healing plug. |
![]() |
17. | Harvested bone in a silicon dappen dish prior to its being placed over the seated implants. |
![]() |
18. | Harvested bone placed over implant. |
![]() |
19. | Resorbable cellulose material being placed to stabilize a blood clot. |
![]() |
20. | Cellulose material being sutured in place. |
![]() |
21. | Cellulose material being sutured in place. |
![]() |
22. | Additional harvested bone being placed over implant. |
![]() |
23. | Flap closed with a combination of interrupted and continuous sutures. |
![]() |
24. | Radiograph immediately after implant placement. |
![]() |
25. | View of operative site fourteen weeks after implant placement with marks from infiltration anesthesia. |
![]() |
26. | Another view of the site prior to the uncovering of the implants. |
![]() |
27. | Crestal incision being made. |
![]() |
28. | View of integrated implants prior to the removal of the cut black polyethylene healing plugs. |
![]() |
29. | Guide pins seated in the well of the implants confirming their trajectory and stability. |
![]() |
30. | Plastic healing abutments seated in implant wells. |
![]() |
31. | Mucosa closed with sutures around healing abutments. |
![]() |
32. | Digital image being taken of shade guide against a black metal background to facilitate the fabrication of an aesthetic Integrated Abutment Crown™. |
![]() |
33. | Healing abutments seated in implant wells five weeks after their insertion and prior to their removal for the making of an implant level impression. |
![]() |
34. | View of implant wells and soft tissue sulci. |
![]() |
35. | White 3.0mm plastic impression post being inserted into the 2.0mm implant well. |
![]() |
36. | White 3.0mm plastic impression post being inserted into the 2.0mm implant well. |
![]() |
37. | White 3.0mm plastic impression post being inserted into the 2.0mm implant well. |
![]() |
38. | White plastic impression post receiving its mandatory seating tap. |
![]() |
39. | White plastic impression post receiving its mandatory seating tap. |
![]() |
40. | Impression material being injected around seated impression posts. |
![]() |
41. | View of implant level transfer impression immediately after its removal from the mouth. |
![]() |
42. | Red acrylic being injected around impression posts for the making of an occlusal registration. |
![]() |
43. | Red acrylic on impression posts recording an occlusal registration. |
![]() |
44. | Occlusal registration being removed from implant wells. |
![]() |
45. | White healing abutment being re-inserted. |
![]() |
46. | Integrated Abutment Crowns™ on dental model with acrylic orientation jig. |
![]() |
47. | Buccal view of Integrated Abutment Crowns™ on dental model. |
![]() |
48. | Lingual view of Integrated Abutment Crowns™ on dental model. |
![]() |
49. | Mirror view of Integrated Abutment Crowns™. |
![]() |
50. | White healing abutments prior to their removal for the insertion of the Integrated Abutment Crowns™. |
![]() |
51. | View of implant wells and soft tissue sulci. |
![]() |
52. | Integrated Abutment Crown™ being inserted. |
![]() |
53. | Integrated Abutment Crown™ being inserted. |
![]() |
54. | Integrated Abutment Crown™ being inserted. |
![]() |
55. | A clear acrylic orientation jig is being used to initially position the Integrated Abutment Crowns™. |
![]() |
56. | Plastic temporary abutment mounted in a straight driver to seat the Integrated Abutment Crown™ in the long axis of the abutment shaft and implant well to engage the locking taper. |
![]() |
57. | Plastic temporary abutment mounted in a straight driver to seat the Integrated Abutment Crown™ in the long axis of the abutment shaft and implant well to engage the locking taper. |
![]() |
58. | Blue marking of occlusal contact. |
![]() |
59. | Seated Integrated Abutment Crowns™ after adjustment. |
![]() |
60. | View of seated Integrated Abutment Crowns™ in occlusion immediately after insertion. |
![]() |
61. | Seventeen months post-operative radiograph. |
|
||