Bicon Integrated Abutment Crowns™: Two Stage Placement of Maxillary Lateral Implants, Implant Level Transfer Impression and their Restoration with Integrated Abutment Crowns™ |
||
| First clinical visit: | ||
![]() |
1. | Pre-operative radiograph. |
![]() |
2. | Pre-operative radiograph. |
![]() |
3. | Pre-operative site. |
![]() |
4. | Osteotomy being enlarged with a teal 3.0mm latch reamer rotating at 50 RPM without water irrigation. |
![]() |
5. | Osteotomy being enlarged with a blue 3.5mm latch reamer rotating at 50 RPM without water irrigation. |
![]() |
6. | Osteotomy being enlarged with a red 4.0mm hand reamer. |
![]() |
7. | Osteotomy being prepared with a silver 4.5mm bone expander. |
![]() |
8. | A 4.5mm x 8.0mm HA coated implant being inserted into the osteotomy with an implant inserter/retriever. |
![]() |
9. | Osteotomy being prepared with 2.0mm pilot bur rotating at 1100RPM with external irrigation. |
![]() |
10. | Osteotomy being enlarged with a teal 3.0mm latch reamer rotating at 50 RPM without water irrigation. |
![]() |
11. | Osteotomy being enlarged with a blue 3.5mm hand reamer. |
![]() |
12. | Osteotomy being enlarged with a red 4.0mm hand reamer. |
![]() |
13. | A 4.0mm x 8.0mm HA coated implant being inserted into the osteotomy with an implant inserter/retriever. |
![]() |
14. | View of polyethylene healing plugs seated in the well of the implants. |
![]() |
15. | Post-operative radiograph. |
![]() |
16. | Post-operative radiograph. |
![]() |
17. | Etchant being applied in preparation for the bonding of the transitional prosthesis to adjacent teeth. |
![]() |
18. | Bonding material being applied. |
![]() |
19. | Light curing of bonding material. |
![]() |
20. | Transitional composite material in vacuum-formed template being formed around acrylic sleeve. . |
![]() |
21. | View of finished transitional stabilizing prostheses. |
![]() |
22. | View of finished transitional stabilizing prostheses. |
| Second clinical visit: | ||
![]() |
23. | View after removal of transitional prosthesis prior to the uncovering of the implant and the making of a full arch implant level transfer impression. |
![]() |
24. | Healing plug removed with a healing plug removal instrument. |
![]() |
25. | View of a red 2.0mm guide pin being seated into the well of the implant. |
![]() |
26. | Red 2.0mm impression reamer being inserted onto guide pin to remove any tissue which might inhibit the complete seating of an impression post. |
![]() |
27. | Healing plug being removed with a healing plug removal instrument. |
![]() |
28. | Red 2.0mm plastic impression post being inserted into the 2.0mm well of an integrated implant for the making of an implant level transfer impression. |
![]() |
29. | Green 3.0mm plastic impression post being inserted into the 3.0mm well of an integrated implant for the making of an implant level transfer impression. |
![]() |
30. | Red 2.0mm plastic impression post receiving its mandatory seating tap. |
![]() |
31. | Green 3.0mm plastic impression post receiving its mandatory seating tap. |
![]() |
32. | Impression material being injected around impression posts for the making of a full arch implant level transfer impression. |
| Third clinical visit: | ||
![]() |
33. | Integrated Abutment Crowns™ on stone model. |
![]() |
34. | View of transitional prostheses prior to their removal for the insertion of Integrated Abutment Crowns™. |
![]() |
35. | Red 2.0mm plastic impression post which was used as a temporary abutment is being removed. |
![]() |
36. | Green 3.0mm plastic impression post which was used as a temporary abutment is being removed. |
![]() |
37. | Abutment post being cleaned with an alcohol wipe to remove any debris which might diminish the effectiveness of the locking taper connection. |
![]() |
38. | Well of implant being cleaned with alcohol on a cotton tipped applicator. |
![]() |
39. | Red 2.0mm impression reamer being inserted onto guide pin to remove any tissue which might inhibit the complete seating of an Integrated Abutment Crown™. |
![]() |
40. | Integrated Abutment Crown™ being inserted. |
![]() |
41. | Yellow thermoplastic custom seating jig, which was formed with a crown alignment device, in a crown seating tip attached to a straight handle facilitates directing the tapping forces in the long axis of the abutment post and implant well. |
![]() |
42. | Integrated Abutment Crown™ being inserted. |
![]() |
43. | Yellow thermoplastic custom seating jig, which was formed with a crown alignment device, in a crown seating tip attached to a straight handle facilitates directing the tapping forces in the long axis of the abutment post and implant well. |
![]() |
44. | Facial view immediately after the insertion of two Integrated Abutment Crowns™. |
![]() |
45. | Post operative radiograph after the insertion of an Integrated Abutment Crown™. |
![]() |
46. | Post operative radiograph after the insertion of an Integrated Abutment Crown™. |
| Fourth clinical visit: | ||
![]() |
47. | Well of implant being cleaned after the patient presented with loose right Integrated Abutment Crown™ six weeks post insertion. |
![]() |
48. | Integrated Abutment Crown™ being inserted. |
![]() |
49. | View of right lateral incisor immediately after being retapped. |
![]() |
50. | Floss being used to confirm the fact that the interproximal contacts are passive and will not interfere with the engagement of the locking taper. |
![]() |
51. | Diamond finishing strip being used to lighten the interproximal contact area eliminating the possibility that the contact may prevent the engagement of the locking taper connection. |
![]() |
52. | View of Integrated Abutment Crowns™ immediately after being retapped. |
![]() |
53. | View of Integrated Abutment Crowns™ two months post insertion. |
|
||