Bicon Integrated Abutment Crown™: Two Stage Placement of Three Mandibular Incisor Implants and their Restoration with Integrated Abutment Crowns™ |
||
| First Clinical Visit: | ||
![]() |
1. | Pre-operative radiograph. |
![]() |
2. | Pre-operative site. |
![]() |
3. | Pre-operative smile. |
![]() |
4. | Periotome being used to initiate the extraction. |
![]() |
5. | Periotome being used to initiate the extraction. |
![]() |
6. | Periotome being used to initiate the extraction. |
![]() |
7. | View of extracted tooth. |
![]() |
8. | View of extracted tooth. |
![]() |
9. | Osteotomy being prepared with a 2.0mm pilot bur rotating at 1100RPM with external irrigation. |
![]() |
10. | View of paralleling pin seated in the initial osteotomy confirming its appropriate trajectory. |
![]() |
11. | Paralleling pins confirming appropriate trajectories and acting as guides for subsequent osteotomy. |
![]() |
12. | Paralleling pins seated in pilot osteotomies indicating their trajectories. |
![]() |
13. | Osteotomy being enlarged with an olive green 2.5mm latch reamer rotating at 50RPM without water irrigation. |
![]() |
14. | Harvested bone within the flute of an olive green 2.5mm latch reamer. |
![]() |
15. | Osteotomy being enlarged with an olive green 2.5mm latch reamer rotating at 50RPM without water irrigation. |
![]() |
16. | Osteotomy being enlarged with a teal 3.0mm latch reamer rotating at 50RPM without water irrigation. |
![]() |
17. | Harvested bone within the flute of a teal 3.0mm latch reamer. |
![]() |
18. | Osteotomy being enlarged with a blue 3.5mm latch reamer rotating at 50RPM without water irrigation. |
![]() |
19. | Harvested bone within the flute of a blue 3.5mm latch reamer. |
![]() |
20. | Osteotomy being enlarged with a blue 3.5mm latch reamer rotating at 50RPM without water irrigation. |
![]() |
21. | Harvested bone within the flute of a blue 3.5mm latch reamer. |
![]() |
22. | Osteotomy being enlarged with a blue 3.5mm latch reamer rotating at 50 RPM without water irrigation. |
![]() |
23. | Harvested bone within the flute of a blue 3.5mm latch reamer. |
![]() |
24. | Currette being used to confirm the integrity of the five walls of the osteotomy. |
![]() |
25. | Currette being used to harvest the bone. |
![]() |
26. | A 3.5mm x 11.0mm HA coated implant being inserted into the osteotomy with a black polyethylene healing plug. |
![]() |
27. | A 3.5mm x 11.0mm HA coated implant being inserted into the osteotomy with a black polyethylene healing plug. |
![]() |
28. | A 3.5mm x 11.0mm HA coated implant being inserted into the osteotomy with a black polyethylene healing plug. |
![]() |
29. | Trimmed polyethylene healing plug being inserted into the well of the implant. |
![]() |
30. | Harvested bone collected in the silicon dappen dish. |
![]() |
31. | Harvested bone being placed over the implants. |
![]() |
32. | View of harvested bone being packed with a cotton tip applicator. |
![]() |
33. | View of Bicon Resorbable Collagen Plug being inserted. |
![]() |
34. | Suture being placed. |
![]() |
35. | Sutured site. |
![]() |
36. | Post-operative radiograph. |
| Second Clinical Visit: (Four months after previous visit) | ||
![]() |
37. | View of operative site, 3 months after implant placement, prior to the two stage uncovering and the making of an implant level transfer impression. |
![]() |
38. | Healing plug being removed with a healing plug removal instrument. |
![]() |
39. | Healing plug being removed with a healing plug removal instrument. |
![]() |
40. | A 2.0mm titanium impression post with red 2.0mm plastic sleeve being seated into the well of an integrated implant for the making of an implant level transfer impression. |
![]() |
41. | A 2.0mm titanium impression post with red 2.0mm plastic sleeve being seated into the well of an integrated implant for the making of an implant level transfer impression. |
![]() |
42. | A 2.0mm titanium impression post with red 2.0mm plastic sleeve being seated into the well of an integrated implant for the making of an implant level transfer impression. |
![]() |
43. | View of seated 2.0mm titanium impression posts with red 2.0mm plastic sleeves. |
![]() |
44. | Impression material being injected around the impression sleeves for the making of a full arch implant level transfer impression. |
| Third Clinical Visit: (Six weeks after previous visit) | ||
![]() |
45. | View of Integrated Abutment Crowns™ on the stone model. |
![]() |
46. | View of Integrated Abutment Crowns™. |
![]() |
47. | View of transitional prosthesis prior to its removal, 3 weeks after the taking of an implant level transfer impression. |
![]() |
48. | Transitional prosthesis being removed. |
![]() |
49. | Well of implant being cleaned with alcohol on a cotton tipped applicator. |
![]() |
50. | Integrated Abutment Crown™ being inserted. |
![]() |
51. | Integrated Abutment Crown™ being inserted. |
![]() |
52. | Integrated Abutment Crown™ being inserted. |
![]() |
53. | White healing abutment in a straight handle is being used to tap the Integrated Abutment Crown™ into the well of the implant. |
![]() |
54. | White healing abutment in a straight handle is being used to tap the Integrated Abutment Crown™ into the well of the implant. |
![]() |
55. | White healing abutment in a straight handle is being used to tap the Integrated Abutment Crown™ into the well of the implant. |
![]() |
56. | View of seated Integrated Abutment Crowns™ immediately after insertion. |
![]() |
57. | Post insertion radiograph. |
![]() |
58. | Four month post insertion facial view of Integrated Abutment Crowns™. |
![]() |
59. | Four month post insertion radiograph. |
![]() |
60. | One year post insertion facial view of Integrated Abutment Crowns™. |
|
||