Bicon Integrated Abutment Crowns™ / Congenitally Missing Laterals: Two Stage Placement and Restoration of a Congenitally Missing Maxillary Left Lateral Incisor Implant with an Integrated Abutment Crown™ |
||
First Visit: |
||
![]() |
1. | Pre-operative radiograph. |
![]() |
2. | Pre-operative site. |
![]() |
3. | Pre-operative smile. |
![]() |
4. | Osteotomy being prepared with 2.0mm pilot bur rotating at 1100RPM with external irrigation. |
![]() |
5. | Paralleling pin confirming appropriate trajectory of the osteotomy. |
![]() |
6. | Osteotomy being enlarged with an olive green 2.5mm latch reamer bur rotating at 50RPM without water irrigation. |
![]() |
7. | Osteotomy being enlarged with a teal 3.0mm latch reamer bur rotating at 50RPM without water irrigation |
![]() |
8. | Osteotomy being enlarged with a blue 3.5mm hand reamer. |
![]() |
9. | Harvested bone within the flute of blue 3.5mm hand reamer. |
![]() |
10. | A 3.5mm x 8.0mm HA coated implant being inserted with an implant seating tip threaded on a straight driver. |
![]() |
11. | Cut polyethylene healing plug being inserted into the well of the implant. |
![]() |
12. | Sutured site. |
![]() |
13. | Post-operative radiograph. |
Second Visit: – four months after previous visit |
||
![]() |
14. | View of operative site prior to the two stage uncovering four months after the implant placement. |
![]() |
15. | Healing plug being removed with a healing plug removal instrument. |
![]() |
16. | Note the trajectory of the implant. |
![]() |
17. | View of seated 2.0mm titanium impression post with red 2.0mm plastic sleeve. |
![]() |
18. | Impression material being injected around the impression sleeve for the making of a full arch implant level transfer impression. |
Third Visit: – six weeks after previous visit |
||
![]() |
19. | View of transitional removable prosthesis. |
![]() |
20. | Site after removal of transitional prosthesis. |
![]() |
21. | Healing plug being removed with healing plug removal instrument. |
![]() |
22. | Well of implant being cleaned with alcohol on a cotton tipped. applicator. |
![]() |
23. | Integrated Abutment Crown™ being inserted. |
![]() |
24. | Diamond finishing strip being used to lighten the interproximal contact area eliminating the possibility that the contact may prevent the engagement of the locking taper connection. |
![]() |
25. | Yellow thermoplastic custom seating jig, which was formed with a crown alignment device, in a crown seating tip attached to a straight handle facilitates directing the tapping forces in the long axis of the abutment post and implant well. |
![]() |
26. | Integrated Abutment Crown™ being modified with 7408 carbide finishing bur. |
![]() |
27. | Facial view immediately after the definitive seating of the Integrated Abutment Crown™. |
![]() |
28. | Post insertion radiograph. |
![]() |
29. | View of Integrated Abutment Crown™ one month post insertion. |
![]() |
30. | Facial view one month post insertion. |
![]() |
31. | Patient’s smile one month post insertion. |
![]() |
32. | View of Integrated Abutment Crown™ five months post insertion. |
![]() |
33. | Left profile view five months post insertion. |
![]() |
34. | Patient’s smile five months post insertion. |
|
||