Listing for Category: Integrated Abutment Crowns™

thumbnail

Extraction of a Maxillary Left First Premolar and its Replacement with a SHORT® 4.5 x 6.0mm Implant, and Grafting with LPRF, Collagen Membranes, and SynthoGraft™, a pure phase beta tricalcium phosphate

Posted on in Extraction, Integrated Abutment Crowns™

This case demonstrates the extraction of a maxillary left first premolar and its replacement with a SHORT® 4.5 x 6.0mm implant using SynthoGraft™, Leukocyte and Platelet Rich Fibrin (LPRF), and collagen membranes. The osteotomy was carefully prepared using latch and hand reamers in 0.5mm increments despite a buccal bone perforation.

thumbnail

Restoration of a Maxillary Left First Molar with an Abutment-Level Transfer Impression

Posted on in Integrated Abutment Crowns™, Restorative, Uncovering

This case demonstrates the process of fabricating an abutment-level transfer impression and a transitional crown with a 5L Universal Abutment after uncovering the implant in the area of the maxillary left first molar.

thumbnail

Placement and Restoration of a 3.0 x 6.0mm SHORT® Implant in a Seemingly Impossible Clinical Situation

Posted on in Immediate Placement, Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical

This case demonstrates three years of remarkable healing and clinical capabilities of a Bicon implant which was restored with an Integrated Abutment Crown™ (IAC) in a seventy-two-year-old male patient. Due to a variety of extenuating circumstances, a 3.0 x 6.0mm SHORT® Implant was immediately placed with a significant amount of SynthoGraft™, a pure phase beta tricalcium phosphate material, and a collagen membrane in a seemingly impossible clinical situation after the removal of a fractured and infected mandibular lateral incisor.

thumbnail

Restoration of Two Maxillary Premolar SHORT® Implants with Integrated Abutment Crowns™

Posted on in Integrated Abutment Crowns™, Restorative

This case demonstrates the ease and simplicity of restorative visits with Bicon Dental Implants. In addition, this case also demonstrates the three primary ways to rotate a sulcus former and two ways to record an implant-level transfer impression.

thumbnail

Extraction and Immediate Placement of a 3.0 x 8.0mm NARROW™ Implant for a Mandibular Central Incisor and its Restoration with an Integrated Abutment Crown™

Posted on in Extraction, Immediate Placement, Integrated Abutment Crowns™, Restorative, Surgical, Uncovering

This case demonstrates the insertion, restoration, and interdental papillae maturation of a 3.0 x 8.0mm NARROW™ Implant for a mandibular right central incisor over the course of a two-year period. This case also demonstrates the use of a hand reamer attached to a hand reamer extender.

thumbnail

Congenitally Missing Maxillary Lateral Incisor Implant Placement on a Seventeen-Year-Old Female

Posted on in Integrated Abutment Crowns™

With radiographic and clinical images, this case demonstrates the successful implant restoration of a congenitally missing maxillary lateral incisor with an Integrated Abutment Crown™ (IAC) for a seventeen-year-old female, and the subsequent 2.0mm intraoral lengthening of the IAC when she was twenty-five years old to compensate for the continued eruption of her natural teeth over the period of eight years.

thumbnail

Congenitally Missing Maxillary Lateral Incisor Implant Placement on a Fifteen-Year-Old Male

Posted on in Integrated Abutment Crowns™, Restorative

With radiographic and clinical images, this case demonstrates the successful implant restoration of a congenitally missing maxillary lateral incisor with an Integrated Abutment Crown™ (IAC) for a fifteen-year-old male, and the subsequent 2.0mm intraoral lengthening of the IAC when he was twenty-two years old to compensate for the continued eruption of his natural teeth over a period of seven years.

thumbnail

Insertion of Two Mandibular Central Incisor IACs for Two 3.0 x 6.0mm NARROW™ Implants

Posted on in Integrated Abutment Crowns™, Restorative

This case demonstrates the insertion of two mandibular central incisor IACs for Bicon NARROW™ Implants. The 3.0 x 6.0mm implants and 25mm IACs were necessary due to extreme loss of gingival tissue from prior infection. Even with an angulated insertion and placement by a straight threaded handle in a caliper, this case exemplifies how to perform a clinically and aesthetically successful insertion in an extreme situation.

thumbnail

24 Immediately Placed and Loaded Implants

Posted on in Immediate Placement, Integrated Abutment Crowns™, Restorative, Surgical, Uncovering

This case demonstrates the surgical placement and restoration of 24 immediately placed and loaded implants.

 

thumbnail

Internal Sinus Lift with Synthograft™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Sinus Lifts, Surgical

This case demonstrates the surgical placement with an internal sinus lift procedure using SynthoGraft™ pure phase Beta-Tricalcium Phosphate, and the restoration of a 5.0 x 6.0mm Bicon SHORT® Implant with an Integrated Abutment Crown™.

Page 2 of 2012345...1020...Last »