-
Bicon Case Study Library
Welcome to the Bicon Case Study Library. The latest Bicon clinical cases will be regularly posted here. There are currently 286 cases containing over 16392 clinical images. Find Case Studies
-
Recent Cases
- Replacement of 25-Year-Old Maxillary and Mandibular O-Ring Relined Overdentures with Telescopic TRINIA® Prostheses
- Nine-Year Follow-Up and CBCT Imaging of 24 Bicon SHORT® Implants and Integrated Abutment Crowns™ (IACs)
- One-Stage Surgical Placement of Two Maxillary and One Mandibular Congenitally Missing Lateral Incisors with SHORT® Implants
- Insertion and Adjustment of an Eight-Unit Maxillary Telescopic TRINIA® Prosthesis on Four SHORT® Implants
- Implant Placement and Restoration of a Six-Unit Cemented TRINIA® Prosthesis in Only Two Clinical Visits
Categories
- Restorative (271)
- All-Ceramic Crowns (27)
- Bridges (11)
- Fixed (9)
- Integrated Abutment Crowns™ (193)
- Overdentures (13)
- Polyceramic Material Fused to Metal (15)
- Porcelain Fused to Metal (16)
- Telescopic Restorations (11)
- SHORT® Implants (64)
- Surgical (177)
- Extraction (70)
- Immediate Placement (49)
- Immediate Stabilization and Function (71)
- One Stage (2)
- Ridge Splits (15)
- Sinus Lifts (12)
- Two Stage (67)
- Uncovering (41)
- Restorative (271)
Topics
- CAD/CAM (15)
- Congenitally Missing Laterals (21)
- Crestal Relieving Incision (40)
- Crown Insertion (169)
- Guided Surgery (2)
- Impression (169)
- SynthoGraft™ (25)
- TRINIA® (29)
Archives
Listing for Category: Restorative
Two Stage Placement of Two Maxillary Anterior Implants with a Ridge Split and Their Restoration with Integrated Abutment Crowns™
This case demonstrates the sequencing of a maxillary ridge split placement of two maxillary anterior implants with Bicon Resorbable Collagen Plug, implant-level transfer impression, temporizations and restoration of two 4.5 x 8.0mm implants with Bicon Integrated Abutment Crowns™. |
|
---|---|
![]() |
Two-Stage Placement of Four MAX 2.5™ Implants with a 2.5mm Diameter Well and their Restoration with Integrated Abutment Crowns™
This case demonstrates the maxillary anterior placement of four MAX 2.5™ 4.0 x 8.0mm implants with Bicon’s NEW 2.5mm diameter well and their subsequent restoration with Integrated Abutment Crowns™. |
![]() |
One Stage Short Implant for a Mandibular First Molar Restoration
This case demonstrates the use of a 6.0mm wide by 5.7mm long implant to restore a missing mandibular first molar from the one stage surgical placement of the short implant to the implant level impression for and insertion of an Integrated Abutment Crown™ as well as the chair-side closure of an open inter-proximal contact. |
![]() |
Two-Stage Implant Placement, Uncovering, and Implant Restorations with Integrated Abutment Crowns™
This case demonstrates the two-stage placement of two 6.0mm x 5.7mm implants for two maxillary molars, uncovering, implant-level transfer impression, and implant restorations with Bicon Integrated Abutment Crowns™. |
![]() |
Ridge Split with Two-Stage Implant Placement and their Restoration with Integrated Abutment Crowns™
This case demonstrates the two stage placement of two implants, implant level transfer impression, and their restoration with Bicon Integrated Abutment Crowns™ for two lateral incisors. |
![]() |
Two-Stage Implant Placement and Restoration with an Integrated Abutment Crown™ for a Congenitally Missing Maxillary Right Lateral Incisor
This case demonstrates the two-stage placement, uncovering, implant-level transfer impression, and restoration of a congenitally missing right lateral incisor with a Bicon Integrated Abutment Crown™ and a veneer on the maxillary right canine to achieve an aesthetic result. |
![]() |
Internal Sinus Lift with SynthoGraft™, Two- Stage Placement of a 5.0mm x 6.0mm Short Implant, and Restoration with a Bicon Integrated Abutment Crown™
This case demonstrates the use of SynthoGraft™ pure phase Beta-Tricalcium Phosphate for an internal sinus lift, two-stage surgical placement of a 5.0mm x 6.0mm implant and a 6.5mm x 2.5mm Sinus Lift Temporary Abutment, an implant-level impression, and an insertion of an Integrated Abutment Crown™. |
![]() |
Two-Stage Implant Placements and their Restoration with Integrated Abutment Crowns™
This case demonstrates the sequencing of extraction, site preparation with a mandibular ridge split, two-stage implant placements, and implant-level transfer impression of two left mandibular teeth and their restoration with Integrated Abutment Crowns™. |
![]() |
Two Implant-Retained Mandibular Overdenture
This case demonstrates the placement of two implants and bone grafting with Synthograft™, uncovering of the implants, and insertion of two locator abutments with their metal housing caps integrated into the denture. |
![]() |
Extraction, Two-Stage Placements, Uncovering, Clinical Impression, and Restoration with Intraoral Bonding of a Mandibular Molar and Mandibular Bicuspid with a Bicon Integrated Abutment Crown™ and a Bicon Integrated Abutment Crown™ with a Cantilever
This case demonstrates the extraction of two mandibular teeth, two-stage implant placements, uncovering, full arch implant-level transfer impression, and their restorations with an Integrated Abutment Crown and an Integrated Abutment Crown with a cantilever. |