Friday, November 24th 2017 12:51AM EST

Latest Cases

thumbnail

Guided Placement and Restoration of a Missing Second Molar with a 5.0 x 6.0mm Bicon SHORT® Implant and a CEREC® e.max® CAD/CAM Crown

Posted on in SHORT® Implants

Radiographic and clinical images of this case demonstrate the successful guided placement of a 5.0 x 6.0mm Bicon SHORT® Implant on a 63-year-old female and restoration with a CEREC® chairside-designed e.max® abutment crown. The case utilized a pre-op CEREC® designed crown integrated into an XG3D cone beam computed tomography (CBCT) for implant planning down the long axis of the CEREC® designed crown. The final design was emailed to SiCat for construction of a surgical guide with a Bicon Guided Sleeve. This case illustrates guided surgery utilizing the final desired intraoral position of the CEREC® abutment crown to determine the final position of the Bicon implant.

thumbnail

Extraction and Immediate Placement of a 3.0 x 8.0mm NARROW™ Implant for a Mandibular Central Incisor and its Restoration with an Integrated Abutment Crown™

Posted on in Extraction, Immediate Placement, Integrated Abutment Crowns™, Restorative, Surgical, Uncovering

This case demonstrates the insertion, restoration, and interdental papillae maturation of a 3.0 x 8.0mm NARROW™ Implant for a mandibular right central incisor over the course of a two-year period. This case also demonstrates the use of a hand reamer attached to a hand reamer extender.

thumbnail

Placement and Immediate Load of Two Maxillary Central Incisor Implants

Posted on in Extraction, Immediate Placement, Surgical

This case demonstrates the immediate placement and loading of two maxillary central incisor implants using a TRINIA™ and Ceramage transitional prosthesis and two Bicon Universal Abutments to stabilize two immediately placed 4.5 x 8.0mm implants.

thumbnail

Four Immediately Placed and Loaded Maxillary Incisors

Posted on in Extraction, Immediate Placement

This case demonstrates the use of a TRINIA™ transitional prosthesis and four Bicon Universal Abutments to stabilize four immediately placed 4.0 x 6.0mm SHORT® Implants after the extraction of four maxillary incisors.

thumbnail

Restoration of Maxillary and Mandibular Full-Arch Telescopic TRINIA™ Prostheses

Posted on in Restorative, SHORT® Implants, Telescopic Restorations

This case demonstrates the clinical and laboratory procedures for the fabrication of maxillary and mandibular full-arch telescopic TRINIA™ restorations, each using four Bicon SHORT® Implants and cast chrome cobalt copings with Si-tec TK-FRIC retentive attachments in only three clinical visits.

thumbnail

Congenitally Missing Maxillary Lateral Incisor Implant Placement on a Seventeen-Year-Old Female

Posted on in Integrated Abutment Crowns™

With radiographic and clinical images, this case demonstrates the successful implant restoration of a congenitally missing maxillary lateral incisor with an Integrated Abutment Crown™ (IAC) for a seventeen-year-old female, and the subsequent 2.0mm intraoral lengthening of the IAC when she was twenty-five years old to compensate for the continued eruption of her natural teeth over the period of eight years.

thumbnail

Insertion of a Fixed Telescopic TRINIA™ CAD/CAM Prosthesis

Posted on in Fixed, Restorative, Telescopic Restorations

This case demonstrates the cementation of four telescopic copings into a full-arch maxillary TRINIA™ CAD/CAM prosthesis and its insertion onto four Bicon abutments. The telescopic copings, which are bonded to the prosthesis via Ceraresin® Bond (CRB) by Shofu, are used to realign the abutments to better fit the bores of the prosthesis for both comfort and effective use.

thumbnail

Congenitally Missing Maxillary Lateral Incisor Implant Placement on a Fifteen-Year-Old Male

Posted on in Integrated Abutment Crowns™, Restorative

With radiographic and clinical images, this case demonstrates the successful implant restoration of a congenitally missing maxillary lateral incisor with an Integrated Abutment Crown™ (IAC) for a fifteen-year-old male, and the subsequent 2.0mm intraoral lengthening of the IAC when he was twenty-two years old to compensate for the continued eruption of his natural teeth over a period of seven years.

thumbnail

Insertion of Two Mandibular Central Incisor IACs for Two 3.0 x 6.0mm NARROW™ Implants

Posted on in Integrated Abutment Crowns™, Restorative

This case demonstrates the insertion of two mandibular central incisor IACs for Bicon NARROW™ Implants. The 3.0 x 6.0mm implants and 25mm IACs were necessary due to extreme loss of gingival tissue from prior infection. Even with an angulated insertion and placement by a straight threaded handle in a caliper, this case exemplifies how to perform a clinically and aesthetically successful insertion in an extreme situation.

thumbnail

Maxillary Anterior Placement of a 4.0 x 8.0mm Bicon Implant with SynthoGraft™

Posted on in Surgical, Two Stage

This case demonstrates the two-stage placement of a maxillary anterior 4.0 x 8.0mm implant with SynthoGraft™ and Leukocyte and Platelet Rich Fibrin (LPRF).

Page 3 of 2812345...1020...Last »