-
Bicon Case Study Library
Welcome to the Bicon Case Study Library. The latest Bicon clinical cases will be regularly posted here. There are currently 339 cases containing over 19021 clinical images. -
Recent Cases
- Gothic Arch Registration and Insertion of a Maxillary Fixed-Detachable TRINIA Prosthesis Supported by Three Bicon SHORT® Implants
- Uncovering of Four Bicon SHORT® Implants with the Subsequent Removal of Three FDUA Transitional Implants and the Fabrication and Insertion of a Screw-Retained Mandibular Full-Arch TRINIA® Prosthesis
- Fabrication of a Temporary Screw-Retained and a Permanent Telescopic Mandibular TRINIA® Prosthesis Supported by Three FDUA Transitional and Four Bicon SHORT® Implants Respectively for a Fifty-Nine-Year-Old Male Patient
- Replacement of a Failed Full-Arch Maxillary PFM Prosthesis with a TRINIA® Full-Arch Prosthesis Supported on Six Bicon SHORT® Implants Using Fixed-Detachable Universal Abutments and Digital Prosthetic Techniques
- Twelve-Year Radiographic Follow Up of a 6.0 x 5.0mm Bicon SHORT® Implant with an Internal Sinus Lift Using SynthoGraft™ and an Integrated Abutment Crown™ (IAC)
Categories
- Restorative (313)
- All-Ceramic Crowns (27)
- Bridges (12)
- Fixed (15)
- Fixed-Detachable (1)
- Integrated Abutment Crowns™ (218)
- Overdentures (17)
- Polyceramic Material Fused to Metal (15)
- Porcelain Fused to Metal (17)
- Telescopic Restorations (18)
- SHORT® Implants (108)
- Surgical (201)
- Extraction (76)
- Immediate Placement (57)
- Immediate Stabilization and Function (76)
- One Stage (6)
- Ridge Splits (16)
- Sinus Lifts (15)
- Two Stage (78)
- Uncovering (47)
- Restorative (313)
Topics
- Adolescent Patients (3)
- CAD/CAM (26)
- Congenitally Missing Laterals (22)
- Crestal Relieving Incision (41)
- Crown Insertion (172)
- FDUA (1)
- Guided Surgery (11)
- Impression (193)
- Long-Term (3)
- Millable Abutment Blanks (1)
- SynthoGraft™ (39)
- TRINIA® (56)
Archives
Listing for Topics: Impression
![]() |
Two Full-Arch TRINIA® Telescopic Restorations Featuring Seven Implant Placements and the Use of Both Retentive and Custom Cast Copings for a Seventy-Year-Old Patient in Five Clinical Visits
This case demonstrates the extraction of six teeth and the placement of four maxillary implants (two using sinus lift abutments and others using bone grafting procedures with SynthoGraft™ and Bicon Resorbable Collagen Membranes) and three mandibular implants, uncovering of implants and two conventional implant-level transfer impressions, two occlusal bite registrations, insertion of the mandibular TRINIA® restoration with three cemented Retentive Copings on Universal Abutments and the insertion of the maxillary TRINIA® restoration with four custom cast Sci-tec copings on modified Universal Abutments for a seventy-year-old female patient. The entire treatment was achieved in only five clinical visits during a seven-month period without fabricating any new transitional prostheses. |
---|---|
![]() |
Replacing Three 25-Year-Old O-Ring Abutments with Three Universal Abutments for the Fabrication of a Mandibular TRINIA® Telescopic Full-Arch Prosthesis for a Seventy-Three-Year-Old Patient
This case demonstrates the removal of three 25-year-old O-Ring Abutments, implant-level impression technique, gothic arch tracing, placement of three Universal Abutments, cementation of retentive copings, and the insertion of a TRINIA® telescopic full-arch prosthesis on three mandibular implants for a seventy-three-year-old female patient. Additionally, note the complete compatibly and interchangeability of Bicon components manufactured over two decades ago as well as the healthy mucosa and bone levels around twenty-four-year-old implants. |
![]() |
Placement of Two 4.5 x 8.0mm Bicon SHORT® Implants and their Restoration with a Two-Unit and a Single Integrated Abutment Crown™ (IAC) for Two Congenitally Missing Maxillary Lateral Incisors and a Right Canine
This treatment demonstrates the extraction of a deciduous maxillary right lateral incisor and its replacement with a 4.5 x 8.0mm Bicon SHORT® Implant adjacent to a congenitally missing canine, as well as bone grafting with SynthoGraft™ in the area of a congenitally missing maxillary left lateral incisor. The placement, six months later, of a 4.5 x 8.0mm Bicon SHORT® Implant in the area of the maxillary right lateral incisor is also shown, as well as the uncovering of the two implants, their full-arch implant-level transfer impression, and their restoration with a two-unit and a single Integrated Abutment Crown™ (IAC). |
![]() |
Placement and Restoration of a 4.0 x 8.0mm Bicon SHORT® Implant for a Maxillary Left Central Incisor in a 17-Year-Old Female Adolescent
This treatment demonstrates the placement and restoration of a 4.0 x 8.0mm Bicon SHORT® Implant for a female adolescent’s maxillary left central incisor, including the full-arch implant-level transfer impression, laboratory fabrication, insertion, and intraoral modification of an Integrated Abutment Crown™ (IAC), and post-insertion labial frenectomy. |
![]() |
Implant-Level Impression and Insertion of a Full-Arch Maxillary Telescopic TRINIA® Prosthesis on Three Universal Abutments and Retentive Copings
This treatment demonstrates the implant-level impression and insertion of a full-arch maxillary telescopic TRINIA® prosthesis with Retentive Copings, supported by only three 5 Series Universal Abutments on three Bicon SHORT® Implants. |
![]() |
Implant-Level Impression, Laboratory Fabrication, and Insertion of a Full-Arch Maxillary Telescopic TRINIA® Prosthesis on Three Universal Abutments and Retentive Copings in Only Two Restorative Visits
This treatment demonstrates the full-arch implant-level impression, laboratory fabrication, and insertion of a full-arch maxillary telescopic TRINIA® prosthesis supported by only two 4.0 x 6.0mm Bicon SHORT® Implants, and one 5.0 x 6.0mm Bicon SHORT® Implant in only two clinical visits, with a chairside reline of the prosthesis and using three prefabricated Retentive Copings. |
![]() |
17-Year Follow Up for Two Immediately Loaded Maxillary Central Incisors
This case demonstrates the extraction of two failed endodontically-treated maxillary central incisors, the immediate surgical placement and stabilization of two 5.0 x 8.0mm Bicon SHORT® Implants, and their subsequent restoration with two Integrated Abutment Crowns™ (IACs). This case also includes 6-year and 17-year follow-up radiographs and clinical images demonstrating not only impressive long-term bone maintenance, but also superior gingival aesthetics that last. |
![]() |
Two-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a Maxillary Left Second Premolar and its Restoration with an Integrated Abutment Crown™ (IAC)
This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a maxillary left second premolar, the making of its full arch implant-level transfer impression, and its restoration with an Integrated Abutment Crown™ (IAC). |
![]() |
Indirect Abutment-level Impression and Insertion of a New CAD/CAM Hybrid Ceramic Crown for a 6.0 x 5.0mm Bicon SHORT® Implant Five Years After Initial Insertion
This treatment demonstrates the replacement of a CAD/CAM crown for a 6.0 x 5.0mm Bicon SHORT® Implant to improve its aesthetics. A full-arch, indirect abutment-level transfer impression, and the intraoral cementation of a CAD/CAM hybrid ceramic crown to a seated 6 Series Universal Abutment is also shown. |
![]() |
Two-Stage Placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a Maxillary Right Central Incisor Five Months After Grafting a Large Buccal Defect with SynthoGraft™
This treatment demonstrates the two-stage placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a maxillary right central incisor five months after grafting a large buccal defect and using SynthoGraft™, a Collagen Membrane, and a Collagen Plug. Also shown is the making of a full arch implant-level transfer impression and the subsequent restoration of the implant with an Integrated Abutment Crown™ (IAC). |