Bicon Video Library
Welcome to the Bicon Video Library. The latest Bicon videos and webcast replays will be regularly posted here.Find Bicon Videos
-
Recent Videos
Categories
- Webcast Replays (22)
- Introductory (5)
- Case Studies (14)
- Techniques (5)
- Scientific Lectures (12)
- International (7)
- Patient Education (7)
Tags
- 360° Positioning
- Bacterial Seal
- Bone Maintenance
- Clinical Tips
- Crown-Implant Ratio
- Extraction
- Finite Element Analysis
- Gingival Aesthetics
- Haversian Bone
- IAC
- Immediate Stabilization and Function
- Impression
- Locking Taper
- Long Term
- MAX 2.5™
- Piezo
- Placement
- Plateau Design
- Platform Switching
- Ridge Split
- SHORT® Implants
- Sinus Lift
- Sloping Shoulder
- SynthoGraft™
- Uncovering
Archives
- June 2010 (1)
- May 2010 (5)
- April 2010 (2)
- March 2010 (1)
- February 2010 (3)
- January 2010 (2)
- December 2009 (1)
- October 2009 (1)
- September 2009 (1)
- August 2009 (5)
- July 2009 (2)
- June 2009 (2)
- May 2009 (2)
- February 2009 (2)
- January 2009 (2)
- December 2008 (1)
- August 2008 (1)
- July 2008 (1)
- June 2008 (1)
- May 2008 (7)
- August 2007 (3)
- July 2006 (1)
- February 2006 (7)
- September 2005 (12)
- January 2005 (3)
- December 2004 (1)
- March 2003 (1)
- August 2002 (1)
Webcast Replays
Uncovering of a Bicon SHORT® Implant
On June 8, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the uncovering of a 5.0 x 6.0mm Bicon SHORT® Implant and the making of an implant level impression. |
|
|---|---|
Guided Bone Regeneration
On May 7, 2010, Bicon presented a webcast featuring a live demonstration by Dr. Shadi Daher to practitioners around the world. The demonstration included the placement of a 4.5 x 6.0mm Bicon SHORT® Implant using SynthoGraft™. |
|
Lateral Sinus Lift using SynthoGraft™
On May 6, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included a lateral sinus lift using SynthoGraft™. |
|
Ridge Split Technique
On May 5, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included a ridge split using a Piezo surgical unit. |
|
Placement of Three Bicon SHORT® Implants in a Ridge Split
On May 5, 2010, Bicon presented a webcast featuring a live demonstration by Dr. Shadi Daher to practitioners around the world. The demonstration included the placement of three 4.5 x 6.0mm Bicon SHORT® Implants using a ridge split technique. |
|
Placement of a Bicon MAX 2.5™ Implant using an Immediate Stabilization and Function Technique
On April 7, 2010, Bicon presented a webcast featuring a live demonstration by Dr. Shadi Daher and Dr. Vincent Morgan to practitioners around the world. The demonstration included the placement of a 4.5 x 8.0mm Bicon MAX 2.5™ Implant using an Immediate Stabilization and Function Technique, followed by the fabrication of a two-unit splint using temporization sleeves. |
|
Placement of a Bicon SHORT® Implant, Uncovering of a Bicon SHORT® Implant, and Insertion of an Integrated Abutment Crown™
On March 10, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included three cases. The first case was the placement of a 6.0 x 8.0mm Bicon SHORT® Implant using a One Stage Surgical Technique. The second case was an uncovering of a 6.0 x 5.0mm Bicon SHORT® Implant and the making of an implant level impression. The third case was the insertion of an Integrated Abutment Crown™. |
|
Placement of a Bicon SHORT® Implant Using an Internal Sinus Lift and SynthoGraft™
On February 18, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the placement of a 6.0 x 5.0mm Bicon SHORT® Implant using an internal sinus lift and SynthoGraft™. |
|
Extraction of an Endodontically Treated Tooth and Placement of a Bicon SHORT® Implant
On February 8, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the extraction of an previously endodontically treated tooth and the placement of a 5.0 x 8.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique. |
|
Placement of a 4.5 x 8.0mm Bicon SHORT® Implant
On February 8, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the placement of a 4.5 x 8.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique. |
|
Placement of a 5.0 x 6.0mm Bicon SHORT Implant
On January 28, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the placement of a 5.0 x 6.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique. |
|
Uncovering of a 5.0 x 6.0mm Bicon SHORT® Implant
On January 28, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the uncovering of a 5.0 x 6.0mm Bicon SHORT® Implant and the making of an implant level impression. |
|
Placement of Two Bicon SHORT® Implants, One with an Internal Sinus Lift Using SynthoGraft™
On December 17th, 2009, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included the placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an Internal Sinus Lift using SynthoGraft™, accompanied by the placement of 5.0 x 6.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique. |
|
Placement of Two Bicon SHORT® Implants
On October 28th, 2009, Bicon presented a two-way internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners at the Tver State Medical Academy in Russia. The demonstration included the placement of a 4.5 x 6.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique, accompanied by the placement of a 5.0 x 6.0mm Bicon SHORT® Implant using an Internal Sinus Lift. |
|
Placement of a Bicon SHORT® Implant using an Internal Sinus Lift and SynthoGraft™
On September 25th , 2009, Bicon presented an internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners in London. The demonstration included the placement of a 6.0 x 5.0mm Bicon SHORT® Implant using an Internal Sinus Lift and SynthoGraft™. |
|
Placement of Two Bicon SHORT® Implants
On July 9th, 2009, Bicon presented a two-way internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners in Tokyo, Japan. The demonstration included the placement of a 5.0 x 6.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique, accompanied by the placement of a 5.0 x 6.0mm Bicon SHORT® Implant using an Internal Sinus Lift. |
|
Floor Transport Technique
On June 25th, 2009, Bicon presented a two-way internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners at the University of Moestopo in Jakarta, Indonesia. The demonstration included the surgical placement of a 5.0 x 6.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique accompanied by the placement of a 6.0 x 5.7mm Bicon SHORT® Implant using the Floor Transport Technique. |
|
Placement of Bicon SHORT® Implants
On June 18th, 2009, Bicon presented a two-way internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners in Barcelona, Spain. The demonstration included the placement of a 4.5 x 6.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique, accompanied by the placement of a 5.0 x 6.0mm Bicon SHORT® Implant using the Floor Transport Technique. |
|
Placement of Bicon SHORT® Implants and Internal Sinus Lift using SynthoGraft™
On May 15th, 2009, Bicon presented an internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners in Tokyo, Japan and Hong Kong, China. The demonstration included two surgical cases. The first case was the placement of two 5.0 x 5.0mm Bicon SHORT® Implants using a Two Stage Surgical Technique. The second case was the placement of a 6.0 x 5.7mm Bicon SHORT® Implant using an Internal Sinus Lift. |
|
Sinus Lift Techniques
On February 20th, 2009 Bicon presented a two-way internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners in Sandton, South Africa. The demonstration included the placement of a 5.0 x 8.0mm Bicon Implant, via an Internal Sinus Lift, accompanied by the placement of a 6.0 x 5.7mm Bicon SHORT® Implant via the Floor Transport Technique. |
|
Placement of a 5.0 x 6.0mm Bicon SHORT® Implant
On January 22nd, 2009 Bicon presented a two-way internet telecast presentation and live demonstration by Doctor Shadi Daher to Bicon practitioners in Tokyo, Japan hosted at Bicon Japan headquarters. The demonstration included an extraction followed by the placement of a 5.0 x 6.0mm Bicon SHORT® Implant. |
|
Internal Sinus Lift Variation: Floor Transport Technique
On June 6th, 2008 Bicon presented a two-way internet telecast presentation and live demonstration by Doctor Shadi Daher to the Royal Society of Medicine in London, England. The demonstration included the floor transport technique for internal sinus lift surgery and the placement of two 6.0mm x 5.7mm Bicon SHORT® implants. |