Tag Archives: Placement

thumbnail

Einsetzen und restaurative Versorgung eines Bicon SHORT® Implantat

Posted on in International, German

Dieses Video beschreibt die Platzierung eines 5,0 x 6,0mm Bicon SHORT Implantat in Regio des zweiten Unterkiefer Molars unter Verwendung der zweiphasigen Chirurgischen Technik und der Restauration mit einer Integrierten Abutment Krone.

thumbnail

Placement and Restoration of a Bicon SHORT® Implant

Posted on in Case Studies

This video depicts the placement of a 5.0 x 6.0mm Bicon SHORT® Implant in the area of the mandibular left second molar using a Two Stage Surgical Technique and the subsequent restoration with an Integrated Abutment Crown™.

thumbnail

Extraction and Placement of a Bicon SHORT® Implant and the Uncovering of a Bicon SHORT® Implant

Posted on in Webcast Replays

On April 1, 2011, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher and Doctor Vincent Morgan to practitioners around the world. The demonstration included two cases. The first case was the extraction and placement of a Bicon SHORT® Implant. The second case was the uncovering of a Bicon SHORT® Implant.

thumbnail

Placement of a Bicon SHORT® Implant and the Uncovering of Two Bicon SHORT® Implants

Posted on in Webcast Replays

On January 27, 2011, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher and Doctor Vincent Morgan to practitioners around the world.  The demonstration included two cases.  The first case was the placement of a Bicon SHORT® Implant.  The second case was the uncovering of two Bicon SHORT® Implants.

thumbnail

Extraction and Placement of Three Bicon SHORT® Implants, Uncovering of Three Bicon SHORT® Implants, and the Insertion of Seven Integrated Abutment Crowns™

Posted on in Webcast Replays

On November 9, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher and Doctor Vincent Morgan to practitioners around the world.  The demonstration included three cases.  The first case was the extraction of two carious teeth and the placement of three Bicon Implants.  The second case was the uncovering of three Bicon SHORT® Implants.  The third case was the insertion of seven Integrated Abutment Crowns™.

thumbnail

Placement of a Bicon SHORT® Implant using SynthoGraft™ and the Uncovering of Two Bicon SHORT® Implants

Posted on in Webcast Replays

On October 16, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher and Doctor Vincent Morgan to practitioners around the world. The demonstration included two cases.  The first case was the placement of a 4.5 x 6.0mm Bicon SHORT® Implant using SynthoGraft™.  The second case was the uncovering of two Bicon SHORT® Implants.

thumbnail

Placement of a Bicon SHORT® Implant using a Floor Transport Technique and the Uncovering of Two Bicon SHORT® Implants

Posted on in Webcast Replays

On October 15, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher and Doctor Vincent Morgan to practitioners around the world. The demonstration included two cases.  The first case was the placement of a 6.0 x 5.7mm Bicon SHORT® Implant using a Floor Transport Technique.  The second case was the uncovering of two Bicon SHORT® Implants.

thumbnail

Mandibular Ridge Split, Placement of Two Bicon SHORT® Implants in a Ridge Split and the Uncovering of Bicon SHORT® Implants Placed in Ridge Splits

Posted on in Webcast Replays

On October 14, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher and Doctor Vincent Morgan to practitioners around the world. The demonstration included three cases.  The first case was a mandibular ridge split using a Piezo Surgery Unit.  The second case was the placement of a 4.5 x 6.0mm and a 4.0 x 5.0mm Bicon SHORT® Implant in a ridge split.  The third case was the uncovering of 5 Bicon SHORT® Implants that had been placed in a ridge split.

thumbnail

Placement of Three Bicon SHORT® Implants using Internal Sinus Lifts and the Insertion of an Integrated Abutment Crown™

Posted on in Webcast Replays

On September 21, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher and Dr. Rainier Urdaneta to practitioners around the world. The demonstration included two cases.  The first case was the placement of a 4.0 x 5.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique and the placement of a 5.0 x 5.0mm and a 6.0 x 5.0mm Bicon SHORT® Implant using Internal Sinus Lifts.  The second case was the insertion of an Integrated Abutment Crown™.

thumbnail

Placement of a Bicon SHORT® Implant and Uncovering of Two Bicon SHORT® Implants

Posted on in Webcast Replays

On September 15, 2010, Bicon presented a webcast featuring a live demonstration by Doctor Shadi Daher to practitioners around the world. The demonstration included two cases.  The first case was the extraction of a carious tooth and the placement of a 4.5 x 8.0mm Bicon SHORT® Implant using a Two Stage Surgical Technique.  The second case was an uncovering of two Bicon SHORT® Implants and the making of an implant level impression.