Friday, March 24th 2023 7:01PM EDT

Fabrication of a Temporary Screw-Retained and a Permanent Telescopic Mandibular TRINIA® Prosthesis Supported by Three FDUA Transitional and Four Bicon SHORT® Implants Respectively for a Fifty-Nine-Year-Old Male Patient

Posted on by Bicon

This case demonstrates the placement and removal of three Fixed-Detachable Universal Abutment (FDUA) Transitional Implants and their successful one year of use supporting a full-arch temporary screw-retained TRINIA® prosthesis with significant bilateral distal extensions. Additionally, the placement, uncovering and prosthetic restoration using impression posts and sleeves with a conventional implant level transfer impression of four Bicon SHORT® Implants is shown. As well as the fabrication of the permanent telescopic TRINIA® prosthesis with four Universal Abutments and Retentive Copings

RESTORATIVE:
TOPICS:

Click on an image to view it larger in a slideshow. Click arrow icons or use keyboard arrow to switch photos. To exit the slideshow, click the X in the upper-right or press ESC.

Click "Switch View" below to change to a layout optimized for printing the case.