This case demonstrates the recording of a Gothic Arch occlusal registration and the insertion of a full-arch TRINIA® prosthesis utilizing three Fixed-Detachable Universal Abutments (FDUAs) with chairside shortened Hex Coping Screws opposing a mandibular telescopic TRINIA® restoration supported by three twenty-four-year-old Bicon NARROW® implants.
Additionally, note the complete compatibly and interchangeability of Bicon components manufactured over two decades ago as well as the healthy mucosa and bone levels around twenty-four-year-old implants.
This is a continuation of a previous case: VIEW CASE
Click on an image to view it larger in a slideshow. Click arrow icons or use keyboard arrow to switch photos. To exit the slideshow, click the X in the upper-right or press ESC.
Click "Switch View" below to change to a layout optimized for printing the case.
Preoperative radiograph with three Brevis Abutments on twenty-four-year-old 3.5 x 11.0mm Bicon NARROW® Implants.
3.
Radiograph with three Brevis Abutments and O-Ring Housings on twenty-four-year-old 3.5 x 11.0mm Bicon NARROW® Implants and three newly placed maxillary Bicon SHORT® Implants.
4.
Radiograph after replacement of three Brevis Abutments with Universal Abutments with Retentive Copings for a telescopic TRINIA® restoration and three newly placed maxillary Bicon SHORT® Implants.
5.
Gothic Arch plate on maxillary wax rim.
6.
Wax rim with two central incisors and Gothic Arch tracing plate.
7.
Gothic Arch drawn on tracing plate and stylus on mandibular plate.
8.
Patient's smile with arrangement of teeth on wax rim.
9.
Conventional occlusal registration of mandibular prosthesis and maxillary waxed teeth arrangement.
10.
Conventional occlusal registration of mandibular prosthesis and maxillary waxed teeth arrangement.
11.
Facial view of TRINIA® prosthesis on stone model.
12.
Occlusal view of TRINIA® prosthesis on stone model.
13.
Clinical view of two Temporary Abutments prior to the uncovering of third implant.
14.
Temporary Abutment being removed.
15.
Fixed-Detachable Universal Abutment (FDUA), Final Coping, and 5.0mm Hex Coping Screw.
16.
Fixed-Detachable Universal Abutment (FDUA) being inserted into well of implant.
17.
FDUA being tapped into well of implant.
18.
TRINIA® prosthesis being placed onto two FDUAs to initially confirm its passive seating.
19.
5.0mm Hex Coping Screw being inserted into anterior FDUA and Final Coping within TRINIA® prosthesis.
20.
5.0mm Hex Coping Screw being inserted into left posterior FDUA and Final Coping within TRINIA® prosthesis.
21.
5.0mm Hex Coping Screw being inserted into right posterior FDUA and Final Coping within TRINIA® prosthesis.
22.
Occlusal view of TRINIA® prosthesis with three Hex Coping Screws prior to their being shortened.
23.
Right posterior Hex Coping Screw being marked prior to being shortened.
24.
5.0mm Hex Coping Screw being shortened with a carbide bur so that, for aesthetic reasons, it will be slightly below the occlusal surface of the prosthesis.
25.
Hex Coping Screws can be shortened by 3.0mm so that it will be slightly below the occlusal height of the prosthesis.
26.
Shortened 5.0mm Hex Coping Screw with a periodontal probe.
27.
Anterior Hex Coping Screw being fastened to FDUA.
28.
Left posterior Hex Coping Screw being fastened to FDUA.
29.
Right posterior Hex Coping Screw being fastened to FDUA.
30.
Composite resin being applied over shortened anterior Hex Coping Screw.
31.
Composite resin being light cured.
32.
Composite resin being applied over shortened left posterior Hex Coping Screw.
33.
Radiographic image of a maxillary screw-retained prosthesis on three Bicon SHORT® Implants and a mandibular telescopic TRINIA® prosthesis on three twenty-four-year-old Bicon NARROW® Implants
Welcome to the Bicon Case Study Library. The latest Bicon clinical cases will be regularly posted here. There are currently 339 cases containing over 19021 clinical images.