Listing for Category: SHORT® Implants

thumbnail

Removal of a Traumatically Fractured Maxillary Left Central Incisor and the Immediate Loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a Universal Abutment for a Nineteen-Year-Old Female Patient

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, Restorative, SHORT® Implants, Surgical

This treatment demonstrates the removal of a maxillary left central incisor six days after its being traumatically fractured, and the immediate loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a 5 Series Tall Profile Universal Abutment and a prosthetically-bonded, stabilizing temporary crown for a nineteen-year-old female patient.

thumbnail

Two-Stage Placement of Two 4.5 x 6.0mm Bicon SHORT® Implants with Bone Grafting of Thin Ridges Using Collagen Membranes, SynthoGraft™, and Autogenous Bone

Posted on in SHORT® Implants

This treatment demonstrates the placement of two 4.5 x 6.0mm Bicon SHORT® Implants with Collagen Membranes, SynthoGraft™, and autogenous bone for the grafting of a right thin ridge with a dehiscence and a left thin ridge without a dehiscence.

thumbnail

Three-Year Radiographic Evaluation of the Placement of a 4.0 x 6.0mm Bicon SHORT® Implant Without Grafting and With Subsequent Bone Gain

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants

Radiographs of a 72-year-old male’s treatment demonstrate the placement of a 4.0 x 6.0mm Bicon SHORT® Implant without grafting and with subsequent bone gain after 34 months. The restoration of the mandibular right central incisor features a 19.5mm-long Integrated Abutment Crown™ (IAC) with a Crown-to-Implant Ratio (CIR) of 3.25 to 1.

thumbnail

Two-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a Maxillary Left Second Premolar and its Restoration with an Integrated Abutment Crown™ (IAC)

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage, Uncovering

This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a maxillary left second premolar, the making of its full arch implant-level transfer impression, and its restoration with an Integrated Abutment Crown™ (IAC).

thumbnail

Indirect Abutment-level Impression and Insertion of a New CAD/CAM Hybrid Ceramic Crown for a 6.0 x 5.0mm Bicon SHORT® Implant Five Years After Initial Insertion

Posted on in SHORT® Implants

This treatment demonstrates the replacement of a CAD/CAM crown for a 6.0 x 5.0mm Bicon SHORT® Implant to improve its aesthetics. A full-arch, indirect abutment-level transfer impression, and the intraoral cementation of a CAD/CAM hybrid ceramic crown to a seated 6 Series Universal Abutment is also shown.

thumbnail

Two-Stage Placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a Maxillary Right Central Incisor Five Months After Grafting a Large Buccal Defect with SynthoGraft™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage

This treatment demonstrates the two-stage placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a maxillary right central incisor five months after grafting a large buccal defect and using SynthoGraft™, a Collagen Membrane, and a Collagen Plug. Also shown is the making of a full arch implant-level transfer impression and the subsequent restoration of the implant with an Integrated Abutment Crown™ (IAC).

thumbnail

One-Stage Placement of a 5.0 x 8.0mm Bicon SHORT® Implant for a Maxillary Left First Molar and its Restoration with an Integrated Abutment Crown™ (IAC)

Posted on in Integrated Abutment Crowns™, One Stage, Restorative, SHORT® Implants, Surgical

This treatment demonstrates the placement of a 5.0 x 8.0mm Bicon SHORT® Implant for a maxillary left first molar using the one-stage surgical technique, the restoration with a full arch implant-level transfer impression, and the insertion of an Integrated Abutment Crown™ (IAC).

thumbnail

Two-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an Internal Sinus Lift Procedure using Guided Surgery for a Maxillary Right First Molar and its Restoration with an Integrated Abutment Crown™ (IAC)

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage

This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an internal sinus lift procedure using guided surgery for a maxillary right first molar and its restoration with an Integrated Abutment Crown™ (IAC). Guided surgery designed for a 5.0 x 5.0mm Bicon SHORT® Implant was used to minimize the risk of sinus perforation and expedite the placement of the 5.0 x 6.0mm Bicon SHORT® Implant with an internal sinus lift procedure. The osteotomy was deepened using incrementally longer Guided Surgery Reamers through the orifice of a 5.0mm Guide Ring until the length of the intended implant was achieved. The top of the Guide Ring is designed to be 12.0mm above the top of the implant when the implant is placed 2.0 to 3.0mm below the alveolar crest of bone.

thumbnail

Laboratory Fabrication of a Full-Arch Maxillary Telescopic TRINIA® Prosthesis and its Insertion on a Demonstration Model

Posted on in SHORT® Implants

This demonstration provides detailed images and explanations of the laboratory fabrication of a custom full-arch maxillary anatomic teeth arrangement for a telescopic TRINIA® prosthesis on four Bicon SHORT® Implants using the polyceramic material, Ceramage, with the live staining sandwich technique and the simulated clinical insertion of the prosthesis on an acrylic demonstration model.

thumbnail

Guided Surgery with Two-Stage Technique for the Restoration of a 5.0 x 8.0mm Bicon SHORT® Implant for a Mandibular Right First Molar with an Integrated Abutment Crown™ (IAC)

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage, Uncovering

Using the Bicon Guided Surgery Technique, a 5.0 x 8.0mm Bicon SHORT® Implant was placed with a two-stage surgery for a mandibular right first molar and restored with an Integrated Abutment Crown™ (IAC). This technique employs a Spade Drill to initially establish the osteotomy to the diameter of the intended implant. Subsequently, the osteotomy was deepened using incrementally longer Guided Surgery Reamers through the orifice of a 5.0mm Guide Ring until the length of the intended implant was achieved. The top of the Guide Ring was designed to be 15.0mm above the top of the implant when the implant is placed 2.0 to 3.0mm below the alveolar crest of bone.