-
Bicon Case Study Library
Welcome to the Bicon Case Study Library. The latest Bicon clinical cases will be regularly posted here. There are currently 328 cases containing over 18604 clinical images. -
Recent Cases
- Fabrication and Insertion of an Extra-Orally Cemented Zirconia Crown on a Custom Abutment Digitally Designed and Milled from a Bicon Abutment Blank
- Occlusal Registration and Insertion of a Mandibular TRINIA® Telescopic Full-Arch Restoration with a 25mm Extension on Two Bicon SHORT® Implants
- Two Full-Arch TRINIA® Telescopic Restorations Featuring Seven Implant Placements and the Use of Both Retentive and Custom Cast Copings for a Seventy-Year-Old Patient in Five Clinical Visits
- Insertion of a Nine-Unit Maxillary TRINIA® Prosthesis on Four Seventeen-Year-Old Implants
- Replacing Three 25-Year-Old O-Ring Abutments with Three Universal Abutments for the Fabrication of a Mandibular TRINIA® Telescopic Full-Arch Prosthesis for a Seventy-Three-Year-Old Patient
Categories
- Restorative (305)
- All-Ceramic Crowns (27)
- Bridges (11)
- Fixed (11)
- Integrated Abutment Crowns™ (215)
- Overdentures (17)
- Polyceramic Material Fused to Metal (15)
- Porcelain Fused to Metal (17)
- Telescopic Restorations (18)
- SHORT® Implants (98)
- Surgical (196)
- Extraction (75)
- Immediate Placement (56)
- Immediate Stabilization and Function (75)
- One Stage (5)
- Ridge Splits (16)
- Sinus Lifts (12)
- Two Stage (77)
- Uncovering (47)
- Restorative (305)
Topics
- CAD/CAM (23)
- Congenitally Missing Laterals (22)
- Crestal Relieving Incision (41)
- Crown Insertion (172)
- Guided Surgery (10)
- Impression (193)
- Long-Term (1)
- SynthoGraft™ (36)
- TRINIA® (47)
Archives
Listing for Category: Surgical
![]() |
Two Full-Arch TRINIA® Telescopic Restorations Featuring Seven Implant Placements and the Use of Both Retentive and Custom Cast Copings for a Seventy-Year-Old Patient in Five Clinical Visits
This case demonstrates the extraction of six teeth and the placement of four maxillary implants (two using sinus lift abutments and others using bone grafting procedures with SynthoGraft™ and Bicon Resorbable Collagen Membranes) and three mandibular implants, uncovering of implants and two conventional implant-level transfer impressions, two occlusal bite registrations, insertion of the mandibular TRINIA® restoration with three cemented Retentive Copings on Universal Abutments and the insertion of the maxillary TRINIA® restoration with four custom cast Sci-tec copings on modified Universal Abutments for a seventy-year-old female patient. The entire treatment was achieved in only five clinical visits during a seven-month period without fabricating any new transitional prostheses. |
---|---|
![]() |
Immediate Loading of Two Bicon SHORT® Implants and Two Temporary Implants With a TRINIA® Prosthesis Using Four Fixed-Detachable Universal Abutment Copings
This case demonstrates the extraction of three maxillary anterior teeth, the placement and immediate loading of two 4.5 x 8.0 mm Bicon SHORT® Implants and two 8.0mm Fixed-Detachable Universal Temporary Implants with a five-unit screw retained TRINIA® prosthesis using four Fixed-Detachable Universal Abutment Copings for an 81-year-old male patient. |
![]() |
Immediate Loading Using Guided Surgery for Two Maxillary Incisor SHORT® Implants with Fixed-Detachable Universal Abutments and a Five-Unit TRINIA® Prosthesis
This case demonstrates the extraction of three maxillary incisor teeth and, using guided surgery, the placement of two 4.5 x 8.0mm SHORT® Implants for immediate loading with a prefabricated five-unit TRINIA® prosthesis on three Fixed-Detachable Universal Abutments, one of which was inserted into a previously-integrated canine implant for a 70-year-old male patient. |
![]() |
Placement of Two 4.5 x 8.0mm Bicon SHORT® Implants and their Restoration with a Two-Unit and a Single Integrated Abutment Crown™ (IAC) for Two Congenitally Missing Maxillary Lateral Incisors and a Right Canine
This treatment demonstrates the extraction of a deciduous maxillary right lateral incisor and its replacement with a 4.5 x 8.0mm Bicon SHORT® Implant adjacent to a congenitally missing canine, as well as bone grafting with SynthoGraft™ in the area of a congenitally missing maxillary left lateral incisor. The placement, six months later, of a 4.5 x 8.0mm Bicon SHORT® Implant in the area of the maxillary right lateral incisor is also shown, as well as the uncovering of the two implants, their full-arch implant-level transfer impression, and their restoration with a two-unit and a single Integrated Abutment Crown™ (IAC). |
![]() |
17-Year Follow Up for Two Immediately Loaded Maxillary Central Incisors
This case demonstrates the extraction of two failed endodontically-treated maxillary central incisors, the immediate surgical placement and stabilization of two 5.0 x 8.0mm Bicon SHORT® Implants, and their subsequent restoration with two Integrated Abutment Crowns™ (IACs). This case also includes 6-year and 17-year follow-up radiographs and clinical images demonstrating not only impressive long-term bone maintenance, but also superior gingival aesthetics that last. |
![]() |
Removal of a Traumatically Fractured Maxillary Left Central Incisor and the Immediate Loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a Universal Abutment for a Nineteen-Year-Old Female Patient
This treatment demonstrates the removal of a maxillary left central incisor six days after its being traumatically fractured, and the immediate loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a 5 Series Tall Profile Universal Abutment and a prosthetically-bonded, stabilizing temporary crown for a nineteen-year-old female patient. |
![]() |
Two-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a Maxillary Left Second Premolar and its Restoration with an Integrated Abutment Crown™ (IAC)
This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a maxillary left second premolar, the making of its full arch implant-level transfer impression, and its restoration with an Integrated Abutment Crown™ (IAC). |
![]() |
Two-Stage Placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a Maxillary Right Central Incisor Five Months After Grafting a Large Buccal Defect with SynthoGraft™
This treatment demonstrates the two-stage placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a maxillary right central incisor five months after grafting a large buccal defect and using SynthoGraft™, a Collagen Membrane, and a Collagen Plug. Also shown is the making of a full arch implant-level transfer impression and the subsequent restoration of the implant with an Integrated Abutment Crown™ (IAC). |
![]() |
One-Stage Placement of a 5.0 x 8.0mm Bicon SHORT® Implant for a Maxillary Left First Molar and its Restoration with an Integrated Abutment Crown™ (IAC)
This treatment demonstrates the placement of a 5.0 x 8.0mm Bicon SHORT® Implant for a maxillary left first molar using the one-stage surgical technique, the restoration with a full arch implant-level transfer impression, and the insertion of an Integrated Abutment Crown™ (IAC). |
![]() |
Two-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an Internal Sinus Lift Procedure using Guided Surgery for a Maxillary Right First Molar and its Restoration with an Integrated Abutment Crown™ (IAC)
This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an internal sinus lift procedure using guided surgery for a maxillary right first molar and its restoration with an Integrated Abutment Crown™ (IAC). Guided surgery designed for a 5.0 x 5.0mm Bicon SHORT® Implant was used to minimize the risk of sinus perforation and expedite the placement of the 5.0 x 6.0mm Bicon SHORT® Implant with an internal sinus lift procedure. The osteotomy was deepened using incrementally longer Guided Surgery Reamers through the orifice of a 5.0mm Guide Ring until the length of the intended implant was achieved. The top of the Guide Ring is designed to be 12.0mm above the top of the implant when the implant is placed 2.0 to 3.0mm below the alveolar crest of bone. |