Listing for Category: Surgical

thumbnail

Replacement of a Failed Full-Arch Maxillary PFM Prosthesis with a TRINIA® Full-Arch Prosthesis Supported on Six Bicon SHORT® Implants Using Fixed-Detachable Universal Abutments and Digital Prosthetic Techniques

Posted on in Fixed, SHORT® Implants, Sinus Lifts

This case demonstrates both the surgical and prosthetic treatments, which provided a seventy-five-year-old professional male patient (who travels frequently) with the comfort of having a fixed maxillary prosthesis throughout his three years of treatment. Initially, a single molar implant was placed with an internal sinus lift procedure, which after its integration provided stability for a fixed transitional prosthesis. Immediately following the extraction of two right premolar teeth and a left molar and their replacement with implants, a transitional prosthesis was inserted.

thumbnail

Twelve-Year Radiographic Follow Up of a 6.0 x 5.0mm Bicon SHORT® Implant with an Internal Sinus Lift Using SynthoGraft™ and an Integrated Abutment Crown™ (IAC)

Posted on in Integrated Abutment Crowns™, SHORT® Implants, Sinus Lifts

This case radiographically demonstrates the extraction, implant placement of a 6.0 x 5.0mm Bicon SHORT® Implant with an internal sinus lift using SynthoGraft™, and restoration with an Integrated Abutment Crown™ (IAC) for a fourty-six-year-old male patient over twelve years. It is also an excellent radiographic example of Wolff’s Law of bone, which states that “bone will adapt to the loads under which it is placed …and become stronger” — form follows function!

thumbnail

Seven-Year Radiographic Follow Up of a 6.0 x 5.0mm Bicon SHORT® Implant Using a Sinus Lift Abutment and an Integrated Abutment Crown™ (IAC)

Posted on in Extraction, Integrated Abutment Crowns™, Sinus Lifts

This case radiographically demonstrates the extraction, implant placement of a 6.0 x 5.0mm Bicon SHORT® Implant with a Sinus Lift Abutment, and its restoration with a 20mm long Integrated Abutment Crown™ (IAC) in a sixty-nine-year-old male patient over 84 months. It is also an excellent radiographic example of Wolff’s Law of bone, which states that “bone will adapt to the loads under which it is placed …and become stronger” — form follows function!

thumbnail

One-Stage Immediate Placement of a Bicon SHORT® Implant Using a Scannable Temporary Abutment for the Restoration of a Mandibular Incisor in Only Two Clinical Visits

Posted on in Immediate Placement, Integrated Abutment Crowns™, One Stage, SHORT® Implants

This case demonstrates the extraction of a mandibular lower left central incisor, the one-stage immediate placement of a 3.5 x 8.0mm SHORT® Implant with a 4-Series Scannable Temporary Abutment with a 2.0mm post, digital impression scanning, temporization with a TRINIA® prosthesis, and the insertion of an Integrated Abutment Crown™ (IAC) for a 72-year-old male patient in only two clinical visits!

thumbnail

Placement and Immediate Loading with a Mandibular Full-Arch TRINIA® Prosthesis of Four Fixed-Detachable Universal Abutment Transitional Implants

Posted on in Bridges, Fixed, Immediate Stabilization and Function, Restorative, SHORT® Implants, Surgical, Two Stage

This case demonstrates the placement of two 4.0 x 6.0mm and two 4.0 x 8.0mm Standard Profile Fixed-Detachable Universal Abutment Transitional Implants using guided surgery and their immediate loading with a mandibular full-arch screw-retained TRINIA® prosthesis with cemented copings within the bores of the TRINIA® prosthesis, subsequent to the placement of four Bicon SHORT® Implants also using guided surgery for their 2.0mm pilot osteotomies.

thumbnail

Two Full-Arch TRINIA® Telescopic Restorations Featuring Seven Implant Placements and the Use of Both Retentive and Custom Cast Copings for a Seventy-Year-Old Patient in Five Clinical Visits

Posted on in Extraction, Fixed, Immediate Placement, Restorative, SHORT® Implants, Surgical, Telescopic Restorations, Two Stage, Uncovering

This case demonstrates the extraction of six teeth and the placement of four maxillary implants (two using sinus lift abutments and others using bone grafting procedures with SynthoGraft™ and Bicon Resorbable Collagen Membranes) and three mandibular implants, uncovering of implants and two conventional implant-level transfer impressions, two occlusal bite registrations, insertion of the mandibular TRINIA® restoration with three cemented Retentive Copings on Universal Abutments and the insertion of the maxillary TRINIA® restoration with four custom cast Sci-tec copings on modified Universal Abutments for a seventy-year-old female patient. The entire treatment was achieved in only five clinical visits during a seven-month period without fabricating any new transitional prostheses.

thumbnail

Immediate Loading of Two Bicon SHORT® Implants and Two Transitional Implants With a TRINIA® Prosthesis Using Four Fixed-Detachable Universal Abutment Copings

Posted on in Extraction, Fixed, SHORT® Implants, Surgical

This case demonstrates the extraction of three maxillary anterior teeth, the placement and immediate loading of two 4.5 x 8.0 mm Bicon SHORT® Implants and two 8.0mm Fixed-Detachable Universal Transitional Implants with a five-unit screw retained TRINIA® prosthesis using four Fixed-Detachable Universal Abutment Copings for an 81-year-old male patient.

thumbnail

Immediate Loading Using Guided Surgery for Two Maxillary Incisor SHORT® Implants with Fixed-Detachable Universal Abutments and a Five-Unit TRINIA® Prosthesis

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, SHORT® Implants, Surgical, Two Stage

This case demonstrates the extraction of three maxillary incisor teeth and, using guided surgery, the placement of two 4.5 x 8.0mm SHORT® Implants for immediate loading with a prefabricated five-unit TRINIA® prosthesis on three Fixed-Detachable Universal Abutments, one of which was inserted into a previously-integrated canine implant for a 70-year-old male patient.

thumbnail

Placement of Two 4.5 x 8.0mm Bicon SHORT® Implants and their Restoration with a Two-Unit and a Single Integrated Abutment Crown™ (IAC) for Two Congenitally Missing Maxillary Lateral Incisors and a Right Canine

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Uncovering

This treatment demonstrates the extraction of a deciduous maxillary right lateral incisor and its replacement with a 4.5 x 8.0mm Bicon SHORT® Implant adjacent to a congenitally missing canine, as well as bone grafting with SynthoGraft™ in the area of a congenitally missing maxillary left lateral incisor. The placement, six months later, of a 4.5 x 8.0mm Bicon SHORT® Implant in the area of the maxillary right lateral incisor is also shown, as well as the uncovering of the two implants, their full-arch implant-level transfer impression, and their restoration with a two-unit and a single Integrated Abutment Crown™ (IAC).

thumbnail

17-Year Follow Up for Two Immediately Loaded Maxillary Central Incisors

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, Integrated Abutment Crowns™, Restorative, Surgical

This case demonstrates the extraction of two failed endodontically-treated maxillary central incisors, the immediate surgical placement and stabilization of two 5.0 x 8.0mm Bicon SHORT® Implants, and their subsequent restoration with two Integrated Abutment Crowns™ (IACs). This case also includes 6-year and 17-year follow-up radiographs and clinical images demonstrating not only impressive long-term bone maintenance, but also superior gingival aesthetics that last.