Listing for Category: Extraction

thumbnail

Seven-Year Radiographic Follow Up of a 6.0 x 5.0mm Bicon SHORT® Implant Using a Sinus Lift Abutment and an Integrated Abutment Crown™ (IAC)

Posted on in Extraction, Integrated Abutment Crowns™, Sinus Lifts

This case radiographically demonstrates the extraction, implant placement of a 6.0 x 5.0mm Bicon SHORT® Implant with a Sinus Lift Abutment, and its restoration with a 20mm long Integrated Abutment Crown™ (IAC) in a sixty-nine-year-old male patient over 84 months. It is also an excellent radiographic example of Wolff’s Law of bone, which states that “bone will adapt to the loads under which it is placed …and become stronger” — form follows function!

thumbnail

Two Full-Arch TRINIA® Telescopic Restorations Featuring Seven Implant Placements and the Use of Both Retentive and Custom Cast Copings for a Seventy-Year-Old Patient in Five Clinical Visits

Posted on in Extraction, Fixed, Immediate Placement, Restorative, SHORT® Implants, Surgical, Telescopic Restorations, Two Stage, Uncovering

This case demonstrates the extraction of six teeth and the placement of four maxillary implants (two using sinus lift abutments and others using bone grafting procedures with SynthoGraft™ and Bicon Resorbable Collagen Membranes) and three mandibular implants, uncovering of implants and two conventional implant-level transfer impressions, two occlusal bite registrations, insertion of the mandibular TRINIA® restoration with three cemented Retentive Copings on Universal Abutments and the insertion of the maxillary TRINIA® restoration with four custom cast Sci-tec copings on modified Universal Abutments for a seventy-year-old female patient. The entire treatment was achieved in only five clinical visits during a seven-month period without fabricating any new transitional prostheses.

thumbnail

Immediate Loading of Two Bicon SHORT® Implants and Two Transitional Implants With a TRINIA® Prosthesis Using Four Fixed-Detachable Universal Abutment Copings

Posted on in Extraction, Fixed, SHORT® Implants, Surgical

This case demonstrates the extraction of three maxillary anterior teeth, the placement and immediate loading of two 4.5 x 8.0 mm Bicon SHORT® Implants and two 8.0mm Fixed-Detachable Universal Transitional Implants with a five-unit screw retained TRINIA® prosthesis using four Fixed-Detachable Universal Abutment Copings for an 81-year-old male patient.

thumbnail

Immediate Loading Using Guided Surgery for Two Maxillary Incisor SHORT® Implants with Fixed-Detachable Universal Abutments and a Five-Unit TRINIA® Prosthesis

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, SHORT® Implants, Surgical, Two Stage

This case demonstrates the extraction of three maxillary incisor teeth and, using guided surgery, the placement of two 4.5 x 8.0mm SHORT® Implants for immediate loading with a prefabricated five-unit TRINIA® prosthesis on three Fixed-Detachable Universal Abutments, one of which was inserted into a previously-integrated canine implant for a 70-year-old male patient.

thumbnail

17-Year Follow Up for Two Immediately Loaded Maxillary Central Incisors

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, Integrated Abutment Crowns™, Restorative, Surgical

This case demonstrates the extraction of two failed endodontically-treated maxillary central incisors, the immediate surgical placement and stabilization of two 5.0 x 8.0mm Bicon SHORT® Implants, and their subsequent restoration with two Integrated Abutment Crowns™ (IACs). This case also includes 6-year and 17-year follow-up radiographs and clinical images demonstrating not only impressive long-term bone maintenance, but also superior gingival aesthetics that last.

thumbnail

Removal of a Traumatically Fractured Maxillary Left Central Incisor and the Immediate Loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a Universal Abutment for a Nineteen-Year-Old Female Patient

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, Restorative, SHORT® Implants, Surgical

This treatment demonstrates the removal of a maxillary left central incisor six days after its being traumatically fractured, and the immediate loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a 5 Series Tall Profile Universal Abutment and a prosthetically-bonded, stabilizing temporary crown for a nineteen-year-old female patient.

thumbnail

Implant Placement and Restoration of a Six-Unit Cemented TRINIA® Prosthesis in Only Two Clinical Visits

Posted on in Extraction, Immediate Placement, SHORT® Implants

This treatment demonstrates the extraction of a maxillary lateral incisor and the immediate placement of a 4.0 x 6.0-mm implant with a 2.5-mm well for a 91-year-old man. An implant-level transfer impression was made for an existing integrated molar implant and the immediately placed incisor implant. The existing molar implant, with a 3.0-mm well, was used to provide support for a temporary prosthesis during the four months of healing. The permanent TRINIA® prosthesis with six units of handcrafted polyceramic teeth was cemented at the time of the implant’s uncovering during the patient’s second clinical visit.

thumbnail

Immediate Placement and Restoration of a Maxillary First Molar with an Extra-Orally Cemented E-Max Crown

Posted on in Extraction, Immediate Placement, Restorative, Surgical

This case demonstrates the extraction of a maxillary first molar and the immediate placement of a 6.0 x 6.0mm implant. Additionally, three different impression techniques are presented: implant-level transfer impression, abutment-level transfer impression, and digitally scanned impression flag. Furthermore, the extra-oral cementation of an E-max (lithium disilicate) crown is demonstrated.

thumbnail

Extraction of a Maxillary Left First Premolar and its Replacement with a SHORT® 4.5 x 6.0mm Implant, and Grafting with LPRF, Collagen Membranes, and SynthoGraft™, a pure phase beta tricalcium phosphate

Posted on in Extraction, Integrated Abutment Crowns™

This case demonstrates the extraction of a maxillary left first premolar and its replacement with a SHORT® 4.5 x 6.0mm implant using SynthoGraft™, Leukocyte and Platelet Rich Fibrin (LPRF), and collagen membranes. The osteotomy was carefully prepared using latch and hand reamers in 0.5mm increments despite a buccal bone perforation.

thumbnail

Extraction and Immediate Placement of a 3.0 x 8.0mm Bicon NARROW™ Implant for a Mandibular Central Incisor and its Restoration with an Integrated Abutment Crown™

Posted on in Extraction, Immediate Placement, Integrated Abutment Crowns™, Restorative, Surgical, Uncovering

This case demonstrates the insertion, restoration, and interdental papillae maturation of a 3.0 x 8.0mm Bicon NARROW™ Implant for a mandibular right central incisor over the course of a two-year period. This case also demonstrates the use of a hand reamer attached to a hand reamer extender.