-
Bicon Case Study Library
Welcome to the Bicon Case Study Library. The latest Bicon clinical cases will be regularly posted here. There are currently 339 cases containing over 19040 clinical images. -
Recent Cases
- Gothic Arch Registration and Insertion of a Maxillary Fixed-Detachable TRINIA Prosthesis Supported by Three Bicon SHORT® Implants
- Uncovering of Four Bicon SHORT® Implants with the Subsequent Removal of Three FDUA Transitional Implants and the Fabrication and Insertion of a Screw-Retained Mandibular Full-Arch TRINIA® Prosthesis
- Fabrication of a Temporary Screw-Retained and a Permanent Telescopic Mandibular TRINIA® Prosthesis Supported by Three FDUA Transitional and Four Bicon SHORT® Implants Respectively for a Fifty-Nine-Year-Old Male Patient
- Replacement of a Failed Full-Arch Maxillary PFM Prosthesis with a TRINIA® Full-Arch Prosthesis Supported on Six Bicon SHORT® Implants Using Fixed-Detachable Universal Abutments and Digital Prosthetic Techniques
- Twelve-Year Radiographic Follow Up of a 6.0 x 5.0mm Bicon SHORT® Implant with an Internal Sinus Lift Using SynthoGraft™ and an Integrated Abutment Crown™ (IAC)
Categories
- Restorative (313)
- All-Ceramic Crowns (27)
- Bridges (12)
- Fixed (15)
- Fixed-Detachable (1)
- Integrated Abutment Crowns™ (218)
- Overdentures (17)
- Polyceramic Material Fused to Metal (15)
- Porcelain Fused to Metal (17)
- Telescopic Restorations (18)
- SHORT® Implants (108)
- Surgical (201)
- Extraction (76)
- Immediate Placement (57)
- Immediate Stabilization and Function (76)
- One Stage (6)
- Ridge Splits (16)
- Sinus Lifts (15)
- Two Stage (78)
- Uncovering (47)
- Restorative (313)
Topics
- Adolescent Patients (3)
- CAD/CAM (26)
- Congenitally Missing Laterals (22)
- Crestal Relieving Incision (41)
- Crown Insertion (172)
- FDUA (1)
- Guided Surgery (11)
- Impression (193)
- Long-Term (3)
- Millable Abutment Blanks (1)
- SynthoGraft™ (39)
- TRINIA® (56)
Archives
Listing for Category: Immediate Stabilization and Function
![]() |
Placement and Immediate Loading with a Mandibular Full-Arch TRINIA® Prosthesis of Four Fixed-Detachable Universal Abutment Transitional Implants
This case demonstrates the placement of two 4.0 x 6.0mm and two 4.0 x 8.0mm Standard Profile Fixed-Detachable Universal Abutment Transitional Implants using guided surgery and their immediate loading with a mandibular full-arch screw-retained TRINIA® prosthesis with cemented copings within the bores of the TRINIA® prosthesis, subsequent to the placement of four Bicon SHORT® Implants also using guided surgery for their 2.0mm pilot osteotomies. |
---|---|
![]() |
Immediate Loading Using Guided Surgery for Two Maxillary Incisor SHORT® Implants with Fixed-Detachable Universal Abutments and a Five-Unit TRINIA® Prosthesis
This case demonstrates the extraction of three maxillary incisor teeth and, using guided surgery, the placement of two 4.5 x 8.0mm SHORT® Implants for immediate loading with a prefabricated five-unit TRINIA® prosthesis on three Fixed-Detachable Universal Abutments, one of which was inserted into a previously-integrated canine implant for a 70-year-old male patient. |
![]() |
17-Year Follow Up for Two Immediately Loaded Maxillary Central Incisors
This case demonstrates the extraction of two failed endodontically-treated maxillary central incisors, the immediate surgical placement and stabilization of two 5.0 x 8.0mm Bicon SHORT® Implants, and their subsequent restoration with two Integrated Abutment Crowns™ (IACs). This case also includes 6-year and 17-year follow-up radiographs and clinical images demonstrating not only impressive long-term bone maintenance, but also superior gingival aesthetics that last. |
![]() |
Removal of a Traumatically Fractured Maxillary Left Central Incisor and the Immediate Loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a Universal Abutment for a Nineteen-Year-Old Female Patient
This treatment demonstrates the removal of a maxillary left central incisor six days after its being traumatically fractured, and the immediate loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a 5 Series Tall Profile Universal Abutment and a prosthetically-bonded, stabilizing temporary crown for a nineteen-year-old female patient. |
![]() |
Restoration of Three Immediately Placed and Loaded 4.5 x 8.0mm Bicon SHORT® Implants and a Single One-Stage Placement in the Anterior Maxilla with a Twelve-Year Follow-Up
This treatment demonstrates the one-stage placement of one 4.5 x 8.0mm Bicon SHORT® Implant with a collagen membrane and the immediate placement and loading of three 4.5 x 8.0mm Bicon SHORT® Implants. Also shown is their initial restoration with four Integrated Abutment Crowns™ (IACs), as well as their subsequent restoration of new IACs with wider hemispherical bases eleven years later and an evaluation twelve years after the initial implant placements. |
![]() |
Extraction, Placement and Restoration of Immediately Placed and Functioning Maxillary Central Incisor Implant with an Integrated Abutment Crown™
This case demonstrates the extraction of a failed endodontically treated maxillary central incisor and its replacement with an immediately placed and functioning implant as well as its restoration with an Integrated Abutment Crown™ showing a prosthetic technique for masking the metallic graying of thin gingival tissues from the underlying abutment. |
![]() |
Extraction, Immediate Placement and Stabilization of Five Bicon Implants and their Restoration with Integrated Abutment Crowns™
This case demonstrates the extraction of three maxillary anterior teeth, insertion of five maxillary anterior immediately placed, stabilized, and functioning implants, as well as implant level transfer impression, and their restoration with five Integrated Abutment Crowns™. |
![]() |
Extraction, Immediate Placement, Stabilization and Restoration of Maxillary Central Incisor Implants with Integrated Abutment Crowns™
This case demonstrates the extraction, immediate placement, stabilization of two 5.0mm x 6.0mm Nanotite short implants as well as their restoration with Integrated Abutment Crowns™. |
![]() |
Placement of Immediately Stabilized and Functioning Maxillary Right Canine Implant for a Congenitally Missing Maxillary Right Lateral and its Restoration with Bicon Integrated Abutment Crown™
This case demonstrates the restoration for a congenitally missing maxillary right lateral incisor with an immediate loading and temporization of 4.5mm x 8.0mm HA coated maxillary right canine implant, implant level transfer impression, and insertion of an Integrated Abutment Crown™. |
![]() |
Extraction, Immediate Placement and Stabilization of Sixteen Bicon Implants and their Restoration with Integrated Abutment Crowns™
This case demonstrates the extraction of fourteen teeth, insertion of sixteen immediately placed, stabilized, and functioning implants, implant level transfer impression, and their restoration with Sixteen Integrated Abutment Crowns™. |