-
Bicon Case Study Library
Welcome to the Bicon Case Study Library. The latest Bicon clinical cases will be regularly posted here. There are currently 339 cases containing over 19040 clinical images. -
Recent Cases
- Gothic Arch Registration and Insertion of a Maxillary Fixed-Detachable TRINIA Prosthesis Supported by Three Bicon SHORT® Implants
- Uncovering of Four Bicon SHORT® Implants with the Subsequent Removal of Three FDUA Transitional Implants and the Fabrication and Insertion of a Screw-Retained Mandibular Full-Arch TRINIA® Prosthesis
- Fabrication of a Temporary Screw-Retained and a Permanent Telescopic Mandibular TRINIA® Prosthesis Supported by Three FDUA Transitional and Four Bicon SHORT® Implants Respectively for a Fifty-Nine-Year-Old Male Patient
- Replacement of a Failed Full-Arch Maxillary PFM Prosthesis with a TRINIA® Full-Arch Prosthesis Supported on Six Bicon SHORT® Implants Using Fixed-Detachable Universal Abutments and Digital Prosthetic Techniques
- Twelve-Year Radiographic Follow Up of a 6.0 x 5.0mm Bicon SHORT® Implant with an Internal Sinus Lift Using SynthoGraft™ and an Integrated Abutment Crown™ (IAC)
Categories
- Restorative (313)
- All-Ceramic Crowns (27)
- Bridges (12)
- Fixed (15)
- Fixed-Detachable (1)
- Integrated Abutment Crowns™ (218)
- Overdentures (17)
- Polyceramic Material Fused to Metal (15)
- Porcelain Fused to Metal (17)
- Telescopic Restorations (18)
- SHORT® Implants (108)
- Surgical (201)
- Extraction (76)
- Immediate Placement (57)
- Immediate Stabilization and Function (76)
- One Stage (6)
- Ridge Splits (16)
- Sinus Lifts (15)
- Two Stage (78)
- Uncovering (47)
- Restorative (313)
Topics
- Adolescent Patients (3)
- CAD/CAM (26)
- Congenitally Missing Laterals (22)
- Crestal Relieving Incision (41)
- Crown Insertion (172)
- FDUA (1)
- Guided Surgery (11)
- Impression (193)
- Long-Term (3)
- Millable Abutment Blanks (1)
- SynthoGraft™ (39)
- TRINIA® (56)
Archives
Latest Cases
![]() |
Placement of Two 4.5 x 8.0mm Bicon SHORT® Implants and their Restoration with a Two-Unit and a Single Integrated Abutment Crown™ (IAC) for Two Congenitally Missing Maxillary Lateral Incisors and a Right Canine
This treatment demonstrates the extraction of a deciduous maxillary right lateral incisor and its replacement with a 4.5 x 8.0mm Bicon SHORT® Implant adjacent to a congenitally missing canine, as well as bone grafting with SynthoGraft™ in the area of a congenitally missing maxillary left lateral incisor. The placement, six months later, of a 4.5 x 8.0mm Bicon SHORT® Implant in the area of the maxillary right lateral incisor is also shown, as well as the uncovering of the two implants, their full-arch implant-level transfer impression, and their restoration with a two-unit and a single Integrated Abutment Crown™ (IAC). |
---|---|
![]() |
Placement and Restoration of a 4.0 x 8.0mm Bicon SHORT® Implant for a Maxillary Left Central Incisor in a 17-Year-Old Female Adolescent
This treatment demonstrates the placement and restoration of a 4.0 x 8.0mm Bicon SHORT® Implant for a female adolescent’s maxillary left central incisor, including the full-arch implant-level transfer impression, laboratory fabrication, insertion, and intraoral modification of an Integrated Abutment Crown™ (IAC), and post-insertion labial frenectomy. |
![]() |
Implant-Level Impression and Insertion of a Full-Arch Maxillary Telescopic TRINIA® Prosthesis on Three Universal Abutments and Retentive Copings
This treatment demonstrates the implant-level impression and insertion of a full-arch maxillary telescopic TRINIA® prosthesis with Retentive Copings, supported by only three 5 Series Universal Abutments on three Bicon SHORT® Implants. |
![]() |
Implant-Level Impression, Laboratory Fabrication, and Insertion of a Full-Arch Maxillary Telescopic TRINIA® Prosthesis on Three Universal Abutments and Retentive Copings in Only Two Restorative Visits
This treatment demonstrates the full-arch implant-level impression, laboratory fabrication, and insertion of a full-arch maxillary telescopic TRINIA® prosthesis supported by only two 4.0 x 6.0mm Bicon SHORT® Implants, and one 5.0 x 6.0mm Bicon SHORT® Implant in only two clinical visits, with a chairside reline of the prosthesis and using three prefabricated Retentive Copings. |
![]() |
17-Year Follow Up for Two Immediately Loaded Maxillary Central Incisors
This case demonstrates the extraction of two failed endodontically-treated maxillary central incisors, the immediate surgical placement and stabilization of two 5.0 x 8.0mm Bicon SHORT® Implants, and their subsequent restoration with two Integrated Abutment Crowns™ (IACs). This case also includes 6-year and 17-year follow-up radiographs and clinical images demonstrating not only impressive long-term bone maintenance, but also superior gingival aesthetics that last. |
![]() |
Removal of a Traumatically Fractured Maxillary Left Central Incisor and the Immediate Loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a Universal Abutment for a Nineteen-Year-Old Female Patient
This treatment demonstrates the removal of a maxillary left central incisor six days after its being traumatically fractured, and the immediate loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a 5 Series Tall Profile Universal Abutment and a prosthetically-bonded, stabilizing temporary crown for a nineteen-year-old female patient. |
![]() |
Two-Stage Placement of Two 4.5 x 6.0mm Bicon SHORT® Implants with Bone Grafting of Thin Ridges Using Collagen Membranes, SynthoGraft™, and Autogenous Bone
This treatment demonstrates the placement of two 4.5 x 6.0mm Bicon SHORT® Implants with Collagen Membranes, SynthoGraft™, and autogenous bone for the grafting of a right thin ridge with a dehiscence and a left thin ridge without a dehiscence. |
![]() |
Three-Year Radiographic Evaluation of the Placement of a 4.0 x 6.0mm Bicon SHORT® Implant Without Grafting and With Subsequent Bone Gain
Radiographs of a 72-year-old male’s treatment demonstrate the placement of a 4.0 x 6.0mm Bicon SHORT® Implant without grafting and with subsequent bone gain after 34 months. The restoration of the mandibular right central incisor features a 19.5mm-long Integrated Abutment Crown™ (IAC) with a Crown-to-Implant Ratio (CIR) of 3.25 to 1. |
![]() |
25-Year Follow Up for a Single Canine Bicon Implant
This long-term case study demonstrates the restoration of a failed endodontically-treated canine with a single Bicon implant with eight-year, fourteen-year, and twenty-five-year post insertion follow-up evaluations. Although we have added new restorative options over the years and our implants have become much shorter, these techniques are still used today and showcase the simplicity of restoring a Bicon implant, as if it were a natural tooth. This case also exemplifies the long-term performance and excellent bone maintenance of Bicon over a twenty-five-year period. |
![]() |
Two-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a Maxillary Left Second Premolar and its Restoration with an Integrated Abutment Crown™ (IAC)
This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a maxillary left second premolar, the making of its full arch implant-level transfer impression, and its restoration with an Integrated Abutment Crown™ (IAC). |