Listing for Tag: Bicon Resorbable Collagen Membrane

thumbnail

Restoration of a Maxillary Left Second Premolar with a 4.5 x 5.0mm Bicon SHORT® Implant Using the Two-Stage Technique with SynthoGraft™ and a Collagen Membrane

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage, Uncovering

This treatment demonstrates the restoration of a maxillary left second premolar with a 4.5 x 5.0mm Bicon SHORT® Implant using the two-stage technique with SynthoGraft™ and a Collagen Membrane, as well as the subsequent uncovering, full arch implant-level transfer impression, and insertion of an Integrated Abutment Crown™ (IAC).

thumbnail

Restoration of a 4.5 x 8.0mm Bicon SHORT® Implant for a Maxillary Right Central Incisor Using the Two-Stage Technique with Bone Grafting

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage

This treatment demonstrates the restoration of a 4.5 x 8.0mm Bicon SHORT® Implant for a maxillary right central incisor using the two-stage technique with bone grafting of a labial fenestration using SynthoGraft™ and autogenous bone with a Collagen Membrane.

thumbnail

Placement of Two 4.0 x 6.0mm SHORT® Implants in the areas of Congenitally Missing Maxillary Lateral Incisors with Grafting Procedures

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants

This treatment demonstrates the placement of two 4.0 x 6.0mm SHORT® Implants for the replacement of congenitally missing maxillary lateral incisors using harvested autogenous bone, SynthoGraft™ (a pure phase beta-tricalcium phosphate), collagen membranes, and leukocyte platelet-rich fibrin (LPRF) membranes.

thumbnail

Two Stage Placement, Uncovering and Restoration of a Maxillary Left Central Incisor Using a Zirconia CAD/CAM Coping Cemented to an Abutment and e.max® Crown

Posted on in Surgical, Two Stage, Uncovering

This case demonstrates the extraction, two-stage placement of a 4.0 x 8.0mm implant with 2.5mm well, its uncovering, implant-level transfer impression, and restoration of a maxillary left central incisor using a zirconia CAD/CAM coping cemented to an abutment and e.max® crown.

thumbnail

Restoration of a Maxillary Left Central Incisor with an e.max® CAD/CAM Crown

Posted on in Restorative, SHORT® Implants, Surgical, Two Stage, Uncovering

This case demonstrates the two-stage placement of a 4.5 x 8.0mm  SHORT® Implant, its uncovering, implant-level transfer impression, and restoration for a maxillary left central incisor with an abutment with a titanium base and extra-orally cemented Zirconia coping abutment which was restored with a lithium disilicate crown.

thumbnail

24 Immediately Placed and Loaded Implants

Posted on in Immediate Placement, Integrated Abutment Crowns™, Restorative, Surgical, Uncovering

This case demonstrates the surgical placement and restoration of 24 immediately placed and loaded implants.

 

thumbnail

Maxillary and Mandibular Metal-Free TRINIA™ Prostheses on Bicon Implants

Posted on in Fixed, SHORT® Implants, Surgical, Two Stage, Uncovering

This case demonstrates the two-stage maxillary placement of four Bicon implants, uncovering, implant-level transfer impressions, the concept and clinical techniques for fabricating a maxillary and mandibular metal-free implant supported fixed TRINIA™ prosthesis on Bicon implants.

thumbnail

Extraction and Immediate Placement of a Maxillary Anterior Implant and its Restoration with an Integrated Abutment Crown™

Posted on in Immediate Placement, Integrated Abutment Crowns™, Restorative, Surgical

This case demonstrates the extraction and immediate placement of a 5.0 x 8.0mm implant for a maxillary central incisor and its restoration with an Bicon Integrated Abutment Crown™.

thumbnail

Extraction Site Preparation with Bicon Resorbable Collagen Membrane, Placement, Temporization and Restoration of Three Maxillary Anterior Implants with Integrated Abutment Crowns™

Posted on in Integrated Abutment Crowns™, Restorative

This case demonstrates the sequencing of extraction site preparation with Bicon Resorbable Collagen Membrane, implant placements, temporizations and restoration of three maxillary anterior implants with three Integrated Abutment Crowns™.

thumbnail

Extraction, Two Stage Placement, Grafting with Bicon Resorbable Collagen Membrane and Restoration of Maxillary right lateral Incisor Implant with an Integrated Abutment Crown™

Posted on in Extraction, Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage

This case demonstrates the extraction and two stage immediate placement of a 4.5mm x 6.0mm HA coated maxillary right lateral incisor implant as well as its restoration with a Bicon Integrated Abutment Crown™.