Listing for Topics: Crestal Relieving Incision

thumbnail

17-Year Follow Up for Two Immediately Loaded Maxillary Central Incisors

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, Integrated Abutment Crowns™, Restorative, Surgical

This case demonstrates the extraction of two failed endodontically-treated maxillary central incisors, the immediate surgical placement and stabilization of two 5.0 x 8.0mm Bicon SHORT® Implants, and their subsequent restoration with two Integrated Abutment Crowns™ (IACs). This case also includes 6-year and 17-year follow-up radiographs and clinical images demonstrating not only impressive long-term bone maintenance, but also superior gingival aesthetics that last.

thumbnail

Restoration of a Maxillary Right Central Incisor with an e.max® CAD/CAM Crown

Posted on in Uncovering

This case demonstrates the uncovering and restoration of a maxillary right central incisor 4.0 x 8.0mm Bicon implant with an abutment with a titanium base and extra-orally cemented zirconia sleeve which was restored with a lithium disilicate crown.

thumbnail

Two Five-Unit TRINIA™ Bridges

Posted on in Bridges, Extraction, Restorative, Surgical, Two Stage, Uncovering

This case demonstrates three extractions and the two-stage maxillary placement of eight Bicon implants, uncovering, implant-level transfer impression, and fabrication of two, five-unit TRINIA™ bridges and two extra-orally cemented TRINIA™ crowns.

thumbnail

Two Stage Placement of Mandibular Left First Molar with a 6.0mm x 5.7mm Short Implant and its Restoration with an Integrated Abutment Crown™

Posted on in Extraction, Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage

This case demonstrates the extraction, two stage implant placement, implant level transfer impression, and restoration of mandibular 6.0mm x 5.7mm Short implant with Bicon Integrated Abutment Crown™.

thumbnail

Extraction and Immediate Placement of four Maxillary Anterior Short Implants and their Restoration with Integrated Abutment Crowns™

Posted on in Extraction, Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical

This case demonstrates the extraction and immediate placement of four maxillary anterior 4.5mm x 6.0mm HA coated short implants; as well as implant level transfer impression and their restoration with four Integrated Abutment Crowns™.

thumbnail

Extraction, Placement and Restoration of Immediately Placed and Functioning Maxillary Central Incisor Implant with an Integrated Abutment Crown™

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, Integrated Abutment Crowns™, Restorative, Surgical

This case demonstrates the extraction of a failed endodontically treated maxillary central incisor and its replacement with an immediately placed and functioning implant as well as its restoration with an Integrated Abutment Crown™ showing a prosthetic technique for masking the metallic graying of thin gingival tissues from the underlying abutment.

thumbnail

Two Stage Placement and Restoration of a Congenitally Missing Maxillary Left Lateral Incisor Implant with an Integrated Abutment Crown™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage, Uncovering

This case demonstrates the two stage placement, uncovering, implant level transfer impression, and restoration of a congenitally missing left lateral incisor with Bicon Integrated Abutment Crown™.

thumbnail

A Two Stage Placement of Mandibular Central Incisor Implant and its Restoration with an Integrated Abutment Crown™

Posted on in Extraction, Immediate Placement, Integrated Abutment Crowns™, Restorative, Surgical, Two Stage

This case demonstrates an immediate two stage placement of mandibular central incisor implant, implant level transfer impression and its restoration with an Integrated Abutment Crown™ as well as an aesthetic resolution of open interproximal contacts.

thumbnail

Two Stage Placement of Two Maxillary Lateral Incisor Short Implants and their Restoration with Integrated Abutment Crowns™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants

This case demonstrates the implant placements, implant level transfer impression and restoration of two 4.5mm x 6.0mm short implants for two congenitally missing lateral incisors with Bicon Integrated Abutment Crowns™.

thumbnail

Extraction, Immediate Placement and Stabilization of Five Bicon Implants and their Restoration with Integrated Abutment Crowns™

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, Integrated Abutment Crowns™, Restorative, Surgical

This case demonstrates the extraction of three maxillary anterior teeth, insertion of five maxillary anterior immediately placed, stabilized, and functioning implants, as well as implant level transfer impression, and their restoration with five Integrated Abutment Crowns™.