Listing for Topics: Impression

thumbnail

Placement of Two 4.5 x 8.0mm Bicon SHORT® Implants and their Restoration with a Two-Unit and a Single Integrated Abutment Crown™ (IAC) for Two Congenitally Missing Maxillary Lateral Incisors and a Right Canine

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Uncovering

This treatment demonstrates the extraction of a deciduous maxillary right lateral incisor and its replacement with a 4.5 x 8.0mm Bicon SHORT® Implant adjacent to a congenitally missing canine, as well as bone grafting with SynthoGraft™ in the area of a congenitally missing maxillary left lateral incisor. The placement, six months later, of a 4.5 x 8.0mm Bicon SHORT® Implant in the area of the maxillary right lateral incisor is also shown, as well as the uncovering of the two implants, their full-arch implant-level transfer impression, and their restoration with a two-unit and a single Integrated Abutment Crown™ (IAC).

thumbnail

Placement and Restoration of a 4.0 x 8.0mm Bicon SHORT® Implant for a Maxillary Left Central Incisor in a 17-Year-Old Female Adolescent

Posted on in Integrated Abutment Crowns™, SHORT® Implants

This treatment demonstrates the placement and restoration of a 4.0 x 8.0mm Bicon SHORT® Implant for a female adolescent’s maxillary left central incisor, including the full-arch implant-level transfer impression, laboratory fabrication, insertion, and intraoral modification of an Integrated Abutment Crown™ (IAC), and post-insertion labial frenectomy.

thumbnail

Implant-Level Impression and Insertion of a Full-Arch Maxillary Telescopic TRINIA® Prosthesis on Three Universal Abutments and Retentive Copings

Posted on in SHORT® Implants, Telescopic Restorations

This treatment demonstrates the implant-level impression and insertion of a full-arch maxillary telescopic TRINIA® prosthesis with Retentive Copings, supported by only three 5 Series Universal Abutments on three Bicon SHORT® Implants.

thumbnail

Implant-Level Impression, Laboratory Fabrication, and Insertion of a Full-Arch Maxillary Telescopic TRINIA® Prosthesis on Three Universal Abutments and Retentive Copings in Only Two Restorative Visits

Posted on in Integrated Abutment Crowns™, SHORT® Implants

This treatment demonstrates the full-arch implant-level impression, laboratory fabrication, and insertion of a full-arch maxillary telescopic TRINIA® prosthesis supported by only two 4.0 x 6.0mm Bicon SHORT® Implants, and one 5.0 x 6.0mm Bicon SHORT® Implant in only two clinical visits, with a chairside reline of the prosthesis and using three prefabricated Retentive Copings.

thumbnail

17-Year Follow Up for Two Immediately Loaded Maxillary Central Incisors

Posted on in Extraction, Immediate Placement, Immediate Stabilization and Function, Integrated Abutment Crowns™, Restorative, Surgical

This case demonstrates the extraction of two failed endodontically-treated maxillary central incisors, the immediate surgical placement and stabilization of two 5.0 x 8.0mm Bicon SHORT® Implants, and their subsequent restoration with two Integrated Abutment Crowns™ (IACs). This case also includes 6-year and 17-year follow-up radiographs and clinical images demonstrating not only impressive long-term bone maintenance, but also superior gingival aesthetics that last.

thumbnail

Two-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a Maxillary Left Second Premolar and its Restoration with an Integrated Abutment Crown™ (IAC)

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage, Uncovering

This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a maxillary left second premolar, the making of its full arch implant-level transfer impression, and its restoration with an Integrated Abutment Crown™ (IAC).

thumbnail

Indirect Abutment-level Impression and Insertion of a New CAD/CAM Hybrid Ceramic Crown for a 6.0 x 5.0mm Bicon SHORT® Implant Five Years After Initial Insertion

Posted on in SHORT® Implants

This treatment demonstrates the replacement of a CAD/CAM crown for a 6.0 x 5.0mm Bicon SHORT® Implant to improve its aesthetics. A full-arch, indirect abutment-level transfer impression, and the intraoral cementation of a CAD/CAM hybrid ceramic crown to a seated 6 Series Universal Abutment is also shown.

thumbnail

Two-Stage Placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a Maxillary Right Central Incisor Five Months After Grafting a Large Buccal Defect with SynthoGraft™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage

This treatment demonstrates the two-stage placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a maxillary right central incisor five months after grafting a large buccal defect and using SynthoGraft™, a Collagen Membrane, and a Collagen Plug. Also shown is the making of a full arch implant-level transfer impression and the subsequent restoration of the implant with an Integrated Abutment Crown™ (IAC).

thumbnail

One-Stage Placement of a 5.0 x 8.0mm Bicon SHORT® Implant for a Maxillary Left First Molar and its Restoration with an Integrated Abutment Crown™ (IAC)

Posted on in Integrated Abutment Crowns™, One Stage, Restorative, SHORT® Implants, Surgical

This treatment demonstrates the placement of a 5.0 x 8.0mm Bicon SHORT® Implant for a maxillary left first molar using the one-stage surgical technique, the restoration with a full arch implant-level transfer impression, and the insertion of an Integrated Abutment Crown™ (IAC).

thumbnail

Two-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an Internal Sinus Lift Procedure using Guided Surgery for a Maxillary Right First Molar and its Restoration with an Integrated Abutment Crown™ (IAC)

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage

This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an internal sinus lift procedure using guided surgery for a maxillary right first molar and its restoration with an Integrated Abutment Crown™ (IAC). Guided surgery designed for a 5.0 x 5.0mm Bicon SHORT® Implant was used to minimize the risk of sinus perforation and expedite the placement of the 5.0 x 6.0mm Bicon SHORT® Implant with an internal sinus lift procedure. The osteotomy was deepened using incrementally longer Guided Surgery Reamers through the orifice of a 5.0mm Guide Ring until the length of the intended implant was achieved. The top of the Guide Ring is designed to be 12.0mm above the top of the implant when the implant is placed 2.0 to 3.0mm below the alveolar crest of bone.