Listing for Topics: SynthoGraft™

thumbnail

Maxillary Arch Reconstruction

Posted on in Extraction, Integrated Abutment Crowns™, Restorative, Surgical

This case demonstrates the reconstruction of the maxillary arch completed in three surgical phases. In total, twelve Bicon implants were placed and restored with Integrated Abutment Crowns™ in six clinical visits.

thumbnail

Two Stage Placement of Four Mandibular Posterior SHORT® Implants and their Restoration With Bicon Integrated Abutment Crowns™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage

This case demonstrates the placement of two 4.5 x 6.0mm implants and two 5.0 x 5.0mm implants. The implants were placed in the mandible and were subsequently restored with Bicon Integrated Abutment Crowns™.

thumbnail

Internal Sinus Lift with SynthoGraft™, Two- Stage Placement of a 5.0mm x 6.0mm Short Implant, and Restoration with a Bicon Integrated Abutment Crown™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Sinus Lifts, Surgical, Two Stage

This case demonstrates the use of SynthoGraft™ pure phase Beta-Tricalcium Phosphate for an internal sinus lift, two-stage surgical placement of a 5.0mm x 6.0mm implant and a 6.5mm x 2.5mm Sinus Lift Temporary Abutment, an implant-level impression, and an insertion of an Integrated Abutment Crown™.

thumbnail

Two Implant-Retained Mandibular Overdenture

Posted on in Overdentures, Restorative, Surgical, Uncovering

This case demonstrates the placement of two implants and bone grafting with Synthograft™, uncovering of the implants, and insertion of two locator abutments with their metal housing caps integrated into the denture.

thumbnail

Extraction, Two Stage Placement, Grafting with Bicon Resorbable Collagen Membrane and Restoration of Maxillary right lateral Incisor Implant with an Integrated Abutment Crown™

Posted on in Extraction, Integrated Abutment Crowns™, Restorative, SHORT® Implants, Surgical, Two Stage

This case demonstrates the extraction and two stage immediate placement of a 4.5mm x 6.0mm HA coated maxillary right lateral incisor implant as well as its restoration with a Bicon Integrated Abutment Crown™.

thumbnail

Bone Grafting with SynthoGraft™, Two Stage Full Arch Placement of Nine Maxillary Implants, and their Restoration with Twelve Bicon Integrated Abutment Crowns™

Posted on in Integrated Abutment Crowns™, Restorative, Surgical, Two Stage

This case demonstrates the use of Synthograft™, Pure Phase Beta-Tricalcium Phosphate, for bone grafting, two stage placement and restoration of nine implants, implant level transfer impression, occlusal registration, and insertion of nine Integrated Abutment Crowns™ including three two-unit Integrated Abutment Crowns™ for the intraoral fabrication of a four unit prosthesis and a three unit prosthesis.

thumbnail

Bilateral Sinus Lifts with SynthoGraft™, Two Stage Full Arch Placement of Twelve Maxillary and Two Mandibular Implants, and their Restoration with Fourteen Bicon Integrated Abutment Crowns™

Posted on in Integrated Abutment Crowns™, Restorative, SHORT® Implants, Sinus Lifts, Surgical, Two Stage

This case demonstrates the use of SynthoGraft™, pure phase Beta-Tricalcium Phosphate, for bilateral sinus lifts, two stage placement and restoration of fourteen implants, implant level transfer impressions, occlusal registration, and insertion of fourteen Integrated Abutment Crowns™ including one two-unit Integrated Abutment Crown™ for the intraoral fabrication of a three unit prosthesis.

thumbnail

Two Stage Placement of Two Implants and their Restoration with Integrated Abutment Crowns™ for Two Congenitally Missing Lateral Incisors

Posted on in Integrated Abutment Crowns™, Restorative, Surgical, Two Stage, Uncovering

This case demonstrates poorly positioned implant being explanted, grafting, two stage placement of two 4.5mm x 8.0mm HA coated implants, temporization, uncovering, implant level transfer impression, and their restoration with Bicon Integrated Abutment Crowns™ for two congenitally missing lateral incisors.

thumbnail

Two Stage and Immediate Full Mouth Placement of Twenty-Four Bicon Implants and their Restoration with Integrated Abutment Crowns™

Posted on in Extraction, Immediate Stabilization and Function, Integrated Abutment Crowns™, Restorative, SHORT® Implants, Sinus Lifts, Surgical, Two Stage

This case demonstrates a sinus lift with SynthoGraft™ and the full mouth restoration of twenty-four implants with the placement of fourteen two-stage and ten immediately placed and stabilized implants while using three transitional implants, implant level transfer impressions, occlusal registration, and insertion of twenty-four Integrated Abutment Crowns™.

thumbnail

Sinus Lifts with SynthoGraft™, Ridge Split, Two Stage Placement of Four Maxillary Bicon Implants and their Restoration with Brevis™ Abutments for a maxillary Implant Retained Overdenture

Posted on in Overdentures, Restorative, Ridge Splits, Sinus Lifts, Surgical, Two Stage

This case demonstrates the use of SynthoGraft™, pure phase Beta-Tricalcium Phosphate, for bilateral sinus lifts, subsequent maxillary ridge split, two stage placement of four maxillary implants, and their restoration with Brevis™ abutments and a metal framed implant retained overdenture.